Crystal Engineering CRYSTALCALHP-NPT Automated Gauge Calibration System
Request a quote
Crystal CRYSTALCALHP-NPT is an automated gauge calibration system with 0.1% accuracy to 15,000 psi, 7-10x faster than deadweight testing, includes wizard setup
Product details
| Model | CRYSTALCALHP-NPT |
| Manufacturer | Crystal Engineering |
| Category | General Pressure Calibrators |
| Availability | Made to order |
Description
Overview
The Crystal Engineering CRYSTALCALHP-NPT is an automated pressure gauge and transmitter calibration system that dramatically reduces calibration time while maintaining accuracy and traceability. Delivering 0.1% of reading accuracy up to 15,000 psi (with XP2i as reference standard), this system performs calibrations 7-10 times faster than traditional deadweight testing. Wizard-guided setup and a lightweight 35 lbs design make it ideal for both bench and field calibration work.
Key Features
- 0.1% of reading accuracy up to 15,000 psi (1,000 bar) when using XP2i reference standard
- 0.05% of reading accuracy up to 5,000 psi (300 bar) when using 30 Series reference standard
- 7-10 times faster than traditional deadweight tester method
- Eliminates transcription and calculation errors
- Wizard-guided setup for ease of use and installation
- Lightweight: 35 lbs (16 kg) for portable field deployment
Included Accessories
- Fine Adjust module (P/N 5102)
- Rolling case for transport and setup (P/N 5101)
- MPF-CAP pressure fittings to prevent transit leaks
- Hold-down straps and fluid bottle
- FastCalXP gauge and transmitter calibration software
- USB Security Key and installation CD
- USB-RS232 adapter and 30 Series RS232 cable
- USB Footswitch for FastCalXP (P/N 3327)
- Rebuild kit (P/N 5103)
Applications
- Pressure gauge calibration and verification
- Chart recorder calibration
- Pressure transmitter calibration and testing
- Field pressure instrument certification
Specifications
| Pressure Accuracy (with XP2i reference) | 0.1% of reading up to 15,000 psi (1,000 bar) |
| Pressure Accuracy (with 30 Series reference) | 0.05% of reading up to 5,000 psi (300 bar) |
| Speed Advantage | 7-10 times faster than deadweight testing |
| Weight | 35 lbs (16 kg) |
| Software Included | FastCalXP gauge and transmitter calibration software |
| Compatibility | Gauge, chart recorder, and transmitter calibration |
| Setup | Wizard-guided installation and configuration |
Request a quote
Crystal Engineering CRYSTALCALHP-NPT Automated Gauge Calibration System
Response within 24 hours
No obligation
Direct communication