Stanford Research Systems SR620 Universal Time Interval/Frequency Counter
Stanford Research Systems SR620 time interval/frequency counter with 25 ps resolution, 1.3 GHz range, 11-digit frequency resolution, and statistics for lab and ATE applications.
Product details
| Model | SR620 |
| Manufacturer | Stanford Research Systems |
| Category | Frequency Counters |
| Availability | Made to order |
Description
Overview
The Stanford Research Systems SR620 is a universal time interval and frequency counter designed for laboratory and automated test equipment (ATE) applications. It performs virtually all time and frequency measurements required in a laboratory environment with exceptional accuracy. The instrument's 25 ps rms single-shot timing resolution and low jitter make it one of the highest resolution counters available, suitable for applications ranging from short-term phase-locked loop jitter analysis to long-term drift measurements of atomic clocks.
Key Features
- 25 ps single-shot timing resolution with low jitter
- Frequency measurement from 0.001 Hz to 1.3 GHz
- 11-digit frequency resolution in 1 second
- Time interval, period, pulse-width, rise/fall time, and phase measurements
- Graphical output: histograms, strip charts, and jitter plots on oscilloscope or plotter
- Statistics calculation: mean, standard deviation, Allan variance, min/max
- Flexible arming and triggering options
- Built-in auto-calibration to null insertion delays
- Precision 1 kHz reference output at 50% duty cycle
- GPIB (IEEE-488.2) and RS-232 interfaces
- Two DVM inputs (±20 VDC at 0.3% accuracy) and two DAC outputs
- Optional ovenized timebase with improved long-term stability
Applications
- Phase-locked loop and jitter analysis
- Atomic clock drift and stability measurement
- Frequency and timing standard verification
- Automated test equipment (ATE) and production testing
- Oscillator and crystal stability characterization
Specifications
| Single-Shot Resolution | 25 ps rms |
| Frequency Range | 0.001 Hz to 1.3 GHz |
| Frequency Resolution | 11 digits (1s gate) |
| Measurement Types | Time interval, frequency, pulse-width, rise/fall time, period, phase, events |
| Gate Options | 1 period to 500 seconds |
| DVM Inputs | ±20 VDC, 0.3% accuracy |
| DAC Outputs | 0 to 10 V (2 channels) |
| Graphical Display Points | Up to 250 strip-chart points or histogram bins |
| Interfaces | GPIB (IEEE-488.2), RS-232, parallel printer |
| Reference Output | 1 kHz, 50% duty cycle |
| Standard Timebase Aging | 1 x 10^-6/year |
| Optional Ovenized Timebase Aging | 5 x 10^-10/day |
Request a quote
Stanford Research Systems SR620 Universal Time Interval/Frequency Counter