Fluke Networks CFP2-100-Q-NW CertiFiber Pro 2 Quad OLTS
Request a quote
Fluke Networks CFP2-100-Q-NW is a fiber certification tester with quad OLTS module, three-second autotest, and Encircled Flux compliance without Wi-Fi.
Product details
| Model | CFP2-100-Q-NW |
| Manufacturer | Fluke Networks |
| Category | Fiber Optic Power Meters & Light Sources |
| Availability | Made to order |
Description
Overview
The Fluke Networks CFP2-100-Q-NW CertiFiber Pro 2 is a Tier 1 fiber optic certification solution featuring a quad OLTS module for testing both multimode and singlemode fibers. It performs automated optical loss measurement of two fibers at two wavelengths in three seconds, with integrated distance measurement and optical loss budget calculation.
Key Features
- Three-second autotest optical loss measurement with distance and loss budget calculation
- Automatic Pass/Fail analysis to industry standards or custom limits
- Double-ended Pass/Fail certification of fiber optic connector endfaces
- Graphical indication of endface problems from contamination, pits, chips, and scratches
- Interchangeable power meter adapters for SC, ST, LC, and FC connectors
- Built-in visual fault locator for troubleshooting and polarity determination
- Dual wavelength measurement capability on single fiber links
- Encircled Flux compliant optical launch for multimode fiber
- Test reference cord verification per ISO/IEC 14763-3
Applications
- Fiber optic network installation certification
- Pre-deployment cable qualification and validation
- Multimode and singlemode fiber acceptance testing
- Field troubleshooting and loss verification
Included Accessories
- Versiv Mainframe and Remote
- 2 CertiFiber Pro Quad OLTS modules
- SC/LC Encircled Flux multimode TRC Kit (50 µm)
Specifications
| Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
| Power Measurement Range | 0 dBm to -65 dBm (850 nm), 0 dBm to -70 dBm (other wavelengths) |
| Power Measurement Uncertainty | < ±5% ±32 pW |
| Measurement Linearity | < ±0.1 dB |
| Detector Type | InGaAs |
| Connector Types | SC, LC, ST, FC (interchangeable adapters) |
| Test Time | 3 seconds for two fibers at two wavelengths |
| Singlemode Distance Range | Up to 130 km |
| Encircled Flux Compliant | Yes |
| Re-calibration Period | 1 year |
| Wi-Fi | No |
Request a quote
Fluke Networks CFP2-100-Q-NW CertiFiber Pro 2 Quad OLTS
Response within 24 hours
No obligation
Direct communication