B&K Precision 8616 Programmable DC Electronic Load
Request a quote
B&K Precision 8616 programmable DC electronic load delivers 1200W with CC/CV/CR/CW modes, 16-bit measurement resolution, and transient operation up to 25 kHz.
Product details
| Model | 8616-BK |
| Manufacturer | B&K Precision |
| Category | DC Electronic Loads |
| Availability | Made to order |
Description
Overview
The B&K Precision 8616 is a programmable DC electronic load designed for testing and evaluating DC power supplies, DC-DC converters, and battery systems. It offers 1200W power handling with voltage range of 0-500V and current range of 0-60A, combining high measurement resolution with versatile operating modes.
Key Features
- CC/CV/CR/CW operating modes for flexible load configuration
- 16-bit voltage and current measurement system with 1 mV / 0.1 mA resolution
- Transient mode up to 25 kHz in CC mode for dynamic testing
- List mode function with storage for up to 100 test setups
- Adjustable slew rate in CC mode for precise load control
- Built-in battery test function with voltage level and capacity monitoring
- CR-LED mode to simulate typical LED loading behavior
- Comprehensive protection: OVP/OCP/OPP/OTP and LRV/RRV reverse voltage protection
- Multiple interfaces: USB (USBTMC-compliant), RS232, and GPIB with SCPI command support
Applications
- DC power supply testing and evaluation
- DC-DC converter characterization
- Battery and battery charger testing
- Photovoltaic array testing
- Electronic load development and validation
Included Accessories
- User manual
- Power cord
- Certificate of calibration
- Test report
Specifications
| Power Rating | 1200 W |
| Operating Voltage | 0 to 500 V |
| Rated Current | 0 to 60 A |
| Measurement Resolution - Voltage | 1 mV |
| Measurement Resolution - Current | 0.1 mA |
| Operating Modes | CC, CV, CR, CW |
| Transient Frequency | up to 25 kHz |
| Memory Slots | 100 |
| Interfaces | USB (USBTMC), RS232, GPIB |
| Protection Features | OVP, OCP, OPP, OTP, LRV, RRV |