Fluke Calibration 1586A/1DS/C DAQ-STAQ Multiplexer
Request a quote
DAQ-STAQ Multiplexer module for Fluke 1586A Super-DAQ with ±0.005°C RTD accuracy and up to 40 isolated input channels for automated temperature sensor calibration.
Product details
| Model | 1586A/1DS/C |
| Manufacturer | Fluke Calibration |
| Category | Benchtop Multimeters |
| Availability | Made to order |
Description
Overview
The Fluke Calibration DAQ-STAQ Multiplexer is an expansion module for the Fluke 1586A Super-DAQ precision temperature scanner, providing external channel expansion and enhanced measurement capabilities. It extends the system to support simultaneous measurement of multiple temperature sensors and parameters with industry-leading accuracy, making it essential for high-throughput calibration labs and automated sensor validation applications in pharmaceutical, automotive, aerospace, and semiconductor industries.
Key Features
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
- Best-in-class temperature measurement accuracy: PRTs ±0.005°C, thermocouples ±0.5°C, thermistors ±0.002°C
- Up to 40 isolated universal input channels
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Control automated calibration routines with Fluke Calibration temperature sources such as dry-wells or micro-baths
- Records up to 20 MB of data and setup files to internal non-volatile memory or external USB drive
- Transfer data to PC using USB drive or LAN connection for analysis in Microsoft Excel
- 6.5-digit display resolution for DC voltage, DC current, and resistance
- Data security with Administrator and user profiles for test traceability
- Two independent user-defined alarms per channel
- Mx + B scaling and channel offset zero function
- Supported by TQSoft and TQAero thermal validation software
Applications
- High-volume temperature sensor calibration
- Automated sensor test routines
- Thermal mapping and temperature validation
- Process sensor calibration
- Multi-channel data acquisition and logging
Specifications
| Accuracy - Platinum RTD (PRT) | ±0.005°C |
| Accuracy - Thermocouples | ±0.5°C |
| Accuracy - Thermistors | ±0.002°C |
| Input Channels | Up to 40 isolated universal inputs |
| Scan Speed | Up to 10 channels per second |
| Maximum Input Voltage | 50 V DC |
| Offset Voltage | < 2 µV |
| Display Resolution | 6.5 digits for DC voltage, current, and resistance |
| Data Storage | 20 MB internal non-volatile memory with USB or LAN transfer |
| Operating Modes | Scan, Monitor, Measure, Digital Multimeter (DMM) |
| Measurement Parameters | Thermocouples, RTD, thermistors, DC voltage, DC current, resistance |