BSL Equipment
Home / Data Loggers & Recorders / Data Loggers / Temperature Data Loggers / MadgeTech AVS140-6-900014 Autoclave Validation System

MadgeTech AVS140-6-900014 Autoclave Validation System

MadgeTech · Model: AVS140-6-900014 Made to order
MadgeTech AVS140-6-900014 Autoclave Validation System
Request a quote

MadgeTech AVS140-6 is a complete autoclave validation system with 5 temperature loggers, pressure logger, and secure software for 21 CFR Part 11 compliance.

Model AVS140-6-900014
Manufacturer MadgeTech
Category Temperature Data Loggers
Availability Made to order

Overview

The MadgeTech AVS140-6 is a complete system designed for performing autoclave validations and ensuring compliance with 21 CFR Part 11 regulations. The system includes high-precision temperature and pressure data loggers, a multiplexer interface, and secure software with built-in validation protocols and workbooks. All components come with ISO 17025 accredited calibration certificates.

Key Features

  • 5 HiTemp140 high-temperature data loggers with 1-inch probe and individual calibration certificates
  • 1 PR140 pressure data logger with NPT top connection and calibration certificate
  • HiTemp140 sensors withstand temperatures up to 140°C (284°F) with ±0.1°C (0.18°F) accuracy
  • PR140 pressure sensors provide ±0.03 Bar (±0.435 PSI) accuracy over 20–140°C operating range
  • Stainless steel construction with full submersibility for autoclave environments
  • MadgeTech 4 Secure Software with electronic signatures, access codes, and audit trails
  • Complete IQ/OQ/PQ validation protocols and workbook included

Applications

  • Autoclave validation and performance qualification
  • Pharmaceutical and medical device manufacturing
  • Laboratory sterilization monitoring
  • Regulatory compliance documentation for 21 CFR Part 11

Included Accessories

  • 5 HiTemp140 temperature data loggers with probes
  • 1 PR140 pressure data logger
  • 1 IFC406 multiplexer interface
  • MadgeTech 4 Secure Data Logger Software with IQ/OQ/PQ protocols
  • ISO 17025 accredited calibration certificates for all loggers
System Components 5 HiTemp140 loggers, 1 PR140 logger, 1 IFC406 multiplexer, MadgeTech 4 Secure Software
HiTemp140 Accuracy ±0.1°C (0.18°F)
HiTemp140 Temperature Range 0–140°C (32–284°F)
PR140 Accuracy ±0.03 Bar (±0.435 PSI)
PR140 Temperature Range 20–140°C (68–284°F)
Construction Material Stainless steel
Submersible Yes
Probe Length 1 inch
PR140 Connection NPT top
Software Compliance 21 CFR Part 11
Calibration ISO 17025 accredited