SMC RAPTOR-SL is an auxiliary slave unit providing 5 kVA additional power to expand Raptor systems for higher current injection applications.

Model RAPTOR-SL
Manufacturer SMC
Category Pressure Calibrators
Availability Made to order

Overview

The SMC RAPTOR-SL is an auxiliary slave unit designed to expand the power capacity of existing Raptor primary injection testing systems. Delivering an additional 5 kVA of stabilized power to the high-current secondary circuit, the RAPTOR-SL increases overall system current capability without modifying the master unit or requiring additional power or control interconnections. The slave communicates with the master Raptor unit exclusively via infrared link, simplifying field deployment.

Up to three RAPTOR-SL units can be cascaded with a single master system, providing cumulative power increases for applications requiring sustained current injection in the 4,000 to 15,000 A range. Each unit uses the same pass-through secondary design with centered hole, allowing multiple slaves to be configured in a modular fashion to match the specific compliance voltage and current requirements of the application.

Key Features

  • Additional 5 kVA power per slave unit
  • Infrared communication to master unit—no physical control connections
  • No external power interconnections required
  • Up to 3 slave units per master system
  • Pass-through secondary design with centered hole
  • Automatic detection by master unit
  • Cumulative current capacity up to 15,000 A
  • Compact, portable design matching master unit

Applications

  • High-current primary injection testing requiring extended power
  • Relay and protective device testing at high current levels
  • Circuit breaker and switchgear evaluation with increased compliance voltage
  • Ground grid and earthing system testing over extended cable distances
  • Primary overcurrent testing with high power demand
Unit Type Auxiliary slave unit
Additional Power Output 5 kVA
Communication Method Infrared link to master unit
Control Connections None required (infrared only)
Power Connections None required (infrared control)
Maximum Units per System 3 additional slaves
Cumulative Current Range 4,000 to 15,000 A
Pass-through Design Centered hole for direct current conduction
Master Unit Compatibility RAPTOR-C15, C-25, C-35 and other Raptor masters
Automatic Detection Yes—detected via infrared communication