Viavi MOPM-C1PMH1-MPMUP Optical Power Meter Module
Request a quote
Viavi MOPM-C1PMH1-MPMUP optical power meter module features ultra-performance detector, 750–1700 nm range, dynamic range to –100 dBm, and 250 kHz sampling for fiber optic testing.
Product details
| Model | MOPM-C1PMH1-MPMUP |
| Manufacturer | Viavi |
| Category | Network & Fiber Optic Test |
| Availability | Made to order |
Description
Overview
The Viavi MOPM-C1PMH1-MPMUP is a single-channel optical power meter module for the MAP (Multiple Application Platform) series. This ultra-performance configuration features a thermally stabilized InGaAs detector with ultra-low noise performance and extended dynamic range, making it suitable for demanding fiber optic test applications in laboratory and manufacturing environments.
Key Features
- Ultra-performance InGaAs detector with thermal stabilization
- Dynamic range: +11 dBm to –100 dBm
- Wavelength range: 750–1700 nm
- 250 kHz sampling rate for high-speed applications
- 3 mm detector size for optimal performance
- Ultra-low noise: less than 0.1 pW (peak-to-peak)
- Linearity: ±0.010 dB ±0.1 pW
- Compatible with single-mode and multimode fiber (NA ≤ 0.27)
- Multiple connector options: FC, ST, LC, E2000, MU, MTP, bare fiber
- Data buffer: 100,000 points per channel
- Return loss: greater than 55 dB (typical)
- 1-year recalibration period
- LXI-compliant with Ethernet connectivity and IVI driver support
Applications
- Amplifier characterization and optimization
- Receiver and transmitter testing and validation
- Absolute power measurement in fiber optic systems
- Optical switching time measurement
Specifications
| Optical Performance | All four performance grades are based on indium gallium arsenide (InGaAs) detectors and are suitable for applications using single-mode (SM) or multimode (MM) fiber. They feature high accuracy, high linearity, and extremely low polarization dependent loss (PDL). The general purpose grade provides a measurement range of -70 to +10 dBm. The high-performance detector features thermal stabilization, which results in an extended wavelength range and a power measurement range of -80 to +11 dBm. The high power grade extends high power measurement capability to +27 dBm. The ultra-performance detectors features enhanced thermal stabilization and noise control, which results in a power measurement range of -100 dBm to +11 dBm and best in class noise performance. |
| Feature | General PurposePremium PerformanceUltra PerformanceHigh Power |
| Detector Type | InGaAsTEC InGaAsTEC InGaAsFiltered InGaAs |
| Detector Size | 2 mm3 mm3 mm2 mm |
| Wavelength Range | 800 – 1650 nm750 – 1700 nm750 – 1700 nm800 – 1630 nm |
| Fiber Type¹ | SMF and MMF with NA 0.27 (maximum core size 62.5 μm) SMF and MMF with NA 0.27 (maximum core size 62.5 μm) |
| Dynamic Range | +11 dBm to –70 dBm+11 dBm to –80 dBm+11 dBm to –100 dBm+27 dBm to –45 dBm |
| Uncertainty at Reference Conditions² | ±2.5% (800 – 1510 nm) ±2.4% (1510 – 1600 nm) ±2.7% (1600 – 1635 nm) ±2.2% (800 – 1510 nm) ±2.3% (1510 – 1600 nm) ±2.5% (1600 – 1635 nm) ±2.2% (800 – 1510 nm) ±2.3% (1510 – 1600 nm) ±2.5% (1600 – 1635 nm) ±3.9% (800 – 960 nm) ±3.6% (960 – 1300 nm) ±3.7% (1300 – 1510 nm) ±3.8% (1510 – 1600 nm) ±4.0% (1600 – 1635 nm) |
| Total Uncertainty³ | ±3.2 % ±5 pW (800 – 900 nm) ±5.2 % ±5 pW (900 – 960 nm) ±3.1 % ±5 pW (960 – 1510 nm) ±3.1 % ±5 pW (1510 – 1600 nm) ±3.8 % ±5 pW (1600 – 1635 nm) ±3.0% ±1 pW (800 – 1510 nm) ±3.1% ±1 pW (1510 – 1600 nm) ±3.4% ±1 pW (1600 – 1635 nm) ±3.0% ±0.2 pW (800 – 1510 nm) ±3.1% ±0.2 pW (1510 – 1600 nm) ±3.4% ±0.2 pW (1600 – 1635 nm) ±4.6% ±100 pW (800 – 900 nm) ±7.9% ±100 pW6 (900 – 960nm) ±3.9% ±100 pW (960 – 1300 nm) ±4.4% ±100 pW (1300 – 1510 nm) ±4.5% ±100 pW (1510 – 1600 nm) ±5.2% ±100 pW (1600 – 1635 nm) |
| Return Loss | >55 dB type>55 dB type>55 dB type>55 dB type |
| Relative Uncertainty due to Polarization⁵ | ±0.015 dB±0.01 dB±0.01 dB±0.07 dB |
| Maximum Number of Channels (Panel Mount) | 1,2 or 41,2 or 41,2 or 41,2 or 4 |
| Sampling Time | 4 µs (250 kHz)4 µs (250 kHz)4 µs (250 kHz)4 µs (250 kHz) |
| Averaging Time | 20 µs to 5 s20 µs to 5 s20 µs to 5 s20 µs to 5 s |
| Buffer Size | 100,000 points100,000 points100,000 points100,000 points |
| Supported Connectors⁷ | FC ST LC E2000 MU MTP or bare fiber FC ST LC E2000 MU MTP or bare fiber FC ST LC E2000 MU MTP or bare fiber FC ST LC E2000 MU MTP or bare fiber |
| Re-calibration Period | 1 year1 year1 year1 year |
| Warm-up Time | 30 min30 min30 min30 min |
| Operating Temperature | 5 to 40°C5 to 40°C5 to 33°C5 to 40°C |
| Humidity | 15 – 80% relative humidity, non-condensing15 – 80% relative humidity, non-condensing15 – 80% relative humidity, non-condensing15 – 80% relative humidity, non-condensing |
| Module Weight | 1.2 kg 2.65 lb 1.2 kg 2.65 lb 1.2 kg 2.65 lb 1.2 kg 2.65 lb |
| Remote Head Cable Length | 1.4 m (4.5 ft)1.4 m (4.5 ft)1.4 m (4.5 ft)1.4 m (4.5 ft) |
| Remote Head Weight | 0.6 kg 1.3 lb 0.6 kg 1.3 lb 0.6 kg 1.3 lb 0.6 kg 1.3 lb |
| Model / Part Number | Description |
| MOPM-C1PMH1-MPMxxxx | Single channel |
| Type of Detector | Single ChannelDual ChannnelQuad Channel |
| General Purpose | MOPM-C1PMH1-MPMGPMOPM-C1PMH2-MPMGPMOPM-C1PMH4-MPMGP |
| High Power | MOPM-C1PMH1-MPMHPMOPM-C1PMH2-MPMHPMOPM-C1PMH4-MPMHP |
| Premium Performance | MOPM-C1PMH1-MPMPPMOPM-C1PMH2-MPMPPMOPM-C1PMH4-MPMPP |
| Ultra Performance | MOPM-C1PMH1-MPMUPMOPM-C1PMH2-MPMUPMOPM-C1PMH4-MPMUP |
Request a quote
Viavi MOPM-C1PMH1-MPMUP Optical Power Meter Module
Response within 24 hours
No obligation
Direct communication