Crystal Engineering nVision Reference Recorder
Request a quote
Crystal nVision Reference Recorder is a portable datalogger with 0.025% pressure accuracy, differential pressure support, and 500,000 data points storage
Product details
| Model | Crystal nVision Reference Recorder |
| Manufacturer | Crystal Engineering |
| Category | Multifunction Data Loggers |
| Availability | Made to order |
Description
Overview
The Crystal nVision Reference Recorder is a portable multifunction datalogger that combines reference-grade accuracy with field durability. Rugged enough to operate submerged in 3 feet of water and portable enough for on-site calibration work, the nVision records pressure, differential pressure, temperature, voltage, and switch states with up to 500,000 data points. The integrated graphical display eliminates the need for a PC during field work, while PC connectivity enables live monitoring and generation of tamper-proof digital records.
Key Features
- Gauge and absolute pressure measurement to 15,000 psi (1,000 bar / 100 MPa)
- Differential pressure accuracy to 0.025% of reading
- Multi-parameter logging: switch, voltage, current, and temperature
- 500,000 data point capacity with 10 readings per second from 2 modules
- Live graphical display on device—no PC required for field operations
- Temperature compensation from -20°C to 50°C
- Replaceable CPF adapter to reduce maintenance costs
- Includes A2LA accredited calibration certificate with 5-point temperature test data
Applications
- Field calibration and testing of pressure instruments
- Pressure transmitter and gauge verification
- Multi-parameter data acquisition in harsh environments
- Portable reference standard for field use
Included Accessories
- Replaceable CPF adapter
- A2LA calibration certificate with multi-point test data
Specifications
| Gauge Pressure Range | 0 to 15,000 psi (0 to 1,000 bar / 100 MPa) |
| Differential Pressure Accuracy | 0.025% of reading |
| Measurement Parameters | Gauge Pressure, Absolute Pressure, Differential Pressure, Temperature, Voltage, Current, Switch State |
| Data Storage Capacity | 500,000 data points |
| Sampling Rate | 10 readings per second (with 2 modules) |
| Operating Temperature Compensation | -20°C to 50°C |
| Display | Live graphical display on device |
| Certification | A2LA accredited calibration certificate with 5-point temperature test data |
Request a quote
Crystal Engineering nVision Reference Recorder
Response within 24 hours
No obligation
Direct communication