Megger 230425 AC/DC high-voltage tester with adjustable voltage to 5 kV, front-panel leakage current trip, and automatic failure shutdown for production line testing.

Model 230425
Manufacturer Megger
Category Hipot Testers
Availability Made to order

Overview

The Megger 230425 AC/DC High-Pot Tester is designed for safety and ease of operation during development, maintenance, and production testing. Test voltage is continuously adjustable from zero to full output with a zero-start interlock. The instrument features automatic high voltage shutdown within 50 ms of arcing or exceeding the preset trip level, with visual and audible alarms to alert operators upon failure.

The 230425 includes multiple safety interlocks that prevent high voltage from being applied if the supply ground wire is open or if the hot and neutral wires are interchanged. A lamp confirms proper grounding of the power source.

Key Features

  • AC/DC test voltage selection with slide switch covering unused output jacks
  • Front-panel leakage current trip adjustable from 0.3 to 12 mA (AC) or 0.43 to 17 mA (DC)
  • One-second or continuous testing modes
  • Test voltage range: 0–4 kV (AC) or 0–5 kV (DC)
  • Automatic failure shutdown with visual and audible alarms
  • Recessed high-voltage connections for safety
  • Zero start/reset function in event of failure
  • Meets UL 120-Kiloohm requirement

Applications

  • Rapid production line testing to latest UL standards
  • Development and maintenance testing of electrical components and assemblies
  • Safety verification and insulation breakdown testing
Applied Test Voltage (AC) 0 to 4 kV
Applied Test Voltage (DC) 0 to 5 kV
Leakage Current Trip (AC) 0.3 to 12 mA adjustable
Leakage Current Trip (DC) 0.43 to 17 mA adjustable
Testing Modes One-second or continuous
Automatic Shutdown Time < 50 ms after arcing or trip level exceeded
High-Voltage Connections Recessed design
Safety Features Ground wire detection, hot/neutral interchange detection, zero-start interlock
Standards Compliance Meets UL 120-Kiloohm requirement