BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Mensor CTD9100-COOL Temperature Dry Well Calibrator

Mensor CTD9100-COOL Temperature Dry Well Calibrator

Mensor · Model: CTD9100-COOL Made to order
Mensor CTD9100-COOL Temperature Dry Well Calibrator
Request a quote

Mensor CTD9100-COOL is a dry well calibrator with -55°C to +200°C range, 0.15-0.25 K accuracy, and ±0.05 K stability for field temperature sensor calibration.

Model CTD9100-COOL
Manufacturer Mensor
Category Dry Block Calibrators
Availability Made to order

Overview

The Mensor CTD9100-COOL is a versatile temperature dry well calibrator engineered for applications requiring both cryogenic and elevated temperature calibration. With an operating range of -55°C to +200°C and exceptional accuracy specifications, this calibrator delivers precision results across the full temperature spectrum for critical industrial and laboratory applications.

The unit combines high accuracy with field portability, offering 0.15 K accuracy from -55°C to 100°C and 0.25 K at 200°C. Its RS-485 interface allows seamless integration into automated calibration systems, while universal AC voltage (100-240 V) support accommodates global deployment.

Key Features

  • Wide temperature range from -55°C to +200°C
  • High accuracy: 0.15 K (-55°C to 100°C), 0.25 K (at 200°C)
  • Excellent stability of ±0.05 K
  • Axial uniformity of less than 0.04 K at 200°C
  • High display resolution of 0.01°C up to 100°C
  • Test piece insertion length of 150 mm for long sensors
  • RS-485 interface for system integration
  • Universal AC power supply (100-240 V, 50-60 Hz)
  • Includes calibration report 3.1

Applications

  • Cryogenic temperature sensor calibration
  • Laboratory precision calibration standards
  • Industrial temperature monitoring equipment verification
  • Field calibration of RTDs and thermocouples
  • Process control system verification
Operating Range -55°C to +200°C
Accuracy (-55°C to 100°C) 0.15 K
Accuracy (at 200°C) 0.25 K
Stability ±0.05 K
Uniformity (axial, at 200°C) <0.04 K
Display Resolution (up to 100°C) 0.01°C
Test Piece Insertion Length 150 mm
Interface RS-485
Power Supply AC 100-240 V, 50-60 Hz
Calibration Certificate Calibration report 3.1 included
Mensor CTD9100-COOL Temperature Dry Well Calibrator

Request a quote

Mensor CTD9100-COOL Temperature Dry Well Calibrator

Response within 24 hours
No obligation
Direct communication

By submitting this form, you agree to the processing of your personal data in accordance with our privacy policy.