Fluke Calibration 9009-B Dual Block Calibrator
Request a quote
Fluke 9009-B is a portable dual-block dry calibrator covering -15°C to 350°C with independent temperature control, two wells per block, and NIST-traceable calibration.
Product details
| Model | 24590T |
| Manufacturer | Fluke Calibration |
| Category | Dry Block Calibrators |
| Availability | Made to order |
Description
Overview
The Fluke 9009-B is a portable dual-block temperature calibrator combining a hot block (50°C to 350°C) and independent cold block (-15°C to 110°C) in a single rugged instrument. Housed in a watertight Pelican case, it delivers professional-grade calibration performance with NIST-traceable accuracy.
Key Features
- Independent temperature control for hot and cold blocks
- Two temperature wells in each block for simultaneous calibrations
- Hot block range: 50°C to 350°C
- Cold block range: -15°C to 110°C
- Display accuracy: ±0.2°C (cold block) / ±0.6°C (hot block)
- Stability: ±0.05°C
- Well uniformity: ±0.1°C
- Display resolution: 0.1°C
- Stabilization time: 8 minutes
- RS-232 connection for automated operation
- Includes Model 9930 Interface-it software for PC control
- Compatible with MET/TEMP II automation software
- Rugged, watertight Pelican case design
- Low weight: 10 pounds (4.5 kg)
- Well depth: 4 inches (102 mm)
- NIST-traceable calibration certificates included for both blocks
Applications
- Calibration of temperature sensors and transmitters
- Comparison calibrations with external reference thermometers
- Automated calibration systems via PC control
- Field calibration work requiring portability
- Laboratory and industrial temperature measurements
Included Accessories
- Two 1/4-inch diameter well inserts
- Two 3/16-inch diameter well inserts
- User Manual
- Model 9930 Interface-it software
- RS-232 cable
- Power cord
- NIST-traceable calibration certificate
- Watertight Pelican carrying case
Specifications
| Hot Block Temperature Range | 50°C to 350°C |
| Cold Block Temperature Range | -15°C to 110°C |
| Display Accuracy (Cold Block) | ±0.2°C |
| Display Accuracy (Hot Block) | ±0.6°C |
| Stability | ±0.05°C |
| Well Uniformity | ±0.1°C |
| Display Resolution | 0.1°C |
| Stabilization Time | 8 minutes |
| Number of Wells per Block | 2 |
| Well Depth | 4 inches (102 mm) |
| Well Insert Sizes | 1/16" to 7/16" (1.6 mm to 11.1 mm) |
| Dimensions | 7" H × 10.5" W × 9.75" D (178 × 267 × 248 mm) |
| Weight | 10 lb (4.5 kg) |
| Connectivity | RS-232 |
| Software Included | Model 9930 Interface-it |
Request a quote
Fluke Calibration 9009-B Dual Block Calibrator
Response within 24 hours
No obligation
Direct communication