Isotech JUPITER 4852 SITE is a portable dry block calibrator for temperatures 30°C to 660°C with ±0.015°C stability, designed for on-site calibration work.

Model JUPITER 4852 SITE
Manufacturer Isotech
Category Dry Block Calibrators
Availability Made to order

Overview

The Isotech JUPITER 4852 SITE is a portable dry block calibrator designed for on-site temperature sensor calibration. With a temperature range of 30°C to 660°C and a compact, portable design, it is ideal for field calibration work. The calibration volume of 35 mm diameter by 148 mm deep accommodates various probe sizes.

Key Features

  • Temperature range: 30°C to 660°C
  • Stability: ±0.015°C @ 100°C, ±0.025°C @ 650°C
  • Display resolution: 0.01°C across entire range
  • Fast response with 20-minute heating and 60-minute cooling cycles
  • Portable design for field and site calibration
  • Calibration volume: 35 mm diameter × 148 mm deep
  • Standard insert with 6 pockets: 2 × 4.5 mm, 2 × 6.4 mm, 1 × 8.0 mm, 1 × 9.5 mm (all 140 mm deep)
  • Multiple sensor input support: thermocouple types E, J, K, N, R, S, T and RTD
  • Blackbody source: ±0.3°C accuracy
  • Surface sensor calibrator: ±0.5°C accuracy
  • Display units: °C, °F, K

Applications

  • On-site thermocouple calibration and verification
  • RTD (Resistance Temperature Detector) field calibration
  • Temperature sensor testing at remote locations
  • Industrial calibration work
  • Multi-point temperature measurement loop calibration
Temperature Range 30°C to 660°C
Stability @ 100°C ±0.015°C
Stability @ 650°C ±0.025°C
Display Resolution 0.01°C
Heating Time (30°C to 650°C) 20 minutes
Cooling Time (650°C to 150°C) 60 minutes
Calibration Volume 35 mm diameter × 148 mm deep
Thermocouple Accuracy (E, J, K, N @ 660°C) ±0.2°C
Thermocouple Accuracy (R @ 660°C) ±0.6°C
Thermocouple Accuracy (S @ 660°C) ±0.7°C
RTD Accuracy ±0.05°C ±0.005% RDG
Blackbody Source Accuracy ±0.3°C
Surface Sensor Accuracy ±0.5°C
Power Supply 115V or 230V AC, 50/60 Hz, 1000 Watts
Dimensions 384 mm H × 212 mm W × 312 mm D
Weight 8.5 kg