BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Isotech JUPITER 4852 BASE Dry Block Calibrator

Isotech JUPITER 4852 BASE Dry Block Calibrator

Isotech · Model: JUPITER 4852 BASE Made to order
Isotech JUPITER 4852 BASE Dry Block Calibrator
Request a quote

Isotech JUPITER 4852 BASE is a dry block calibrator for temperatures 30°C to 660°C with ±0.015°C stability for precision temperature sensor calibration.

Model JUPITER 4852 BASE
Manufacturer Isotech
Category Dry Block Calibrators
Availability Made to order

Overview

The Isotech JUPITER 4852 BASE is a precision dry block calibrator for calibrating temperature measurement instruments. With a temperature range of 30°C to 660°C and a calibration volume of 35 mm diameter by 148 mm deep, it accommodates various probe sizes and is suitable for laboratory and field calibration work.

Key Features

  • Temperature range: 30°C to 660°C
  • Stability: ±0.015°C @ 100°C, ±0.025°C @ 650°C
  • Display resolution: 0.01°C across entire range
  • Fast response with 20-minute heating and 60-minute cooling cycles
  • Calibration volume: 35 mm diameter × 148 mm deep
  • Standard insert with 6 pockets: 2 × 4.5 mm, 2 × 6.4 mm, 1 × 8.0 mm, 1 × 9.5 mm (all 140 mm deep)
  • Multiple sensor input support: thermocouple types E, J, K, N, R, S, T and RTD
  • Blackbody source: ±0.3°C accuracy
  • Surface sensor calibrator: ±0.5°C accuracy
  • Display units: °C, °F, K

Applications

  • Thermocouple calibration and verification
  • RTD (Resistance Temperature Detector) calibration
  • Temperature sensor testing and calibration
  • Metrology and calibration laboratory work
  • Multi-point temperature measurement loop calibration
Temperature Range 30°C to 660°C
Stability @ 100°C ±0.015°C
Stability @ 650°C ±0.025°C
Display Resolution 0.01°C
Heating Time (30°C to 650°C) 20 minutes
Cooling Time (650°C to 150°C) 60 minutes
Calibration Volume 35 mm diameter × 148 mm deep
Thermocouple Accuracy (E, J, K, N @ 660°C) ±0.2°C
Thermocouple Accuracy (R @ 660°C) ±0.6°C
Thermocouple Accuracy (S @ 660°C) ±0.7°C
RTD Accuracy ±0.05°C ±0.005% RDG
Blackbody Source Accuracy ±0.3°C
Surface Sensor Accuracy ±0.5°C
Power Supply 115V or 230V AC, 50/60 Hz, 1000 Watts
Dimensions 384 mm H × 212 mm W × 312 mm D
Weight 8.5 kg
Isotech JUPITER 4852 BASE Dry Block Calibrator

Request a quote

Isotech JUPITER 4852 BASE Dry Block Calibrator

Response within 24 hours
No obligation
Direct communication

By submitting this form, you agree to the processing of your personal data in accordance with our privacy policy.