Isotech JUPITER 4852 ADVANCED Dry Block Calibrator
Request a quote
Isotech JUPITER 4852 ADVANCED is a dry block calibrator for temperatures 30°C to 660°C with ±0.015°C stability and automatic temperature cycling.
Product details
| Model | JUPITER 4852 ADVANCED |
| Manufacturer | Isotech |
| Category | Dry Block Calibrators |
| Availability | Made to order |
Description
Overview
The Isotech JUPITER 4852 ADVANCED is a precision dry block calibrator designed for calibrating temperature measurement instruments. The Advanced model features automatic temperature cycling and data logging, enabling efficient calibration across multiple points with minimal operator intervention. With a temperature range of 30°C to 660°C and a calibration volume of 35 mm diameter by 148 mm deep, it accommodates various probe sizes.
Key Features
- Temperature range: 30°C to 660°C
- Stability: ±0.015°C @ 100°C, ±0.025°C @ 650°C
- Display resolution: 0.01°C across entire range
- Fast response with 20-minute heating and 60-minute cooling cycles
- Automatic temperature cycling with data logging (Advanced model)
- Calibration volume: 35 mm diameter × 148 mm deep
- Standard insert with 6 pockets: 2 × 4.5 mm, 2 × 6.4 mm, 1 × 8.0 mm, 1 × 9.5 mm (all 140 mm deep)
- Multiple sensor input support: thermocouple types E, J, K, N, R, S, T and RTD
- Blackbody source: ±0.3°C accuracy
- Surface sensor calibrator: ±0.5°C accuracy
- Display units: °C, °F, K
Applications
- Thermocouple calibration and verification
- RTD (Resistance Temperature Detector) calibration
- Temperature sensor testing and calibration
- Metrology and calibration laboratory work
- Multi-point temperature measurement loop calibration
Specifications
| Temperature Range | 30°C to 660°C |
| Stability @ 100°C | ±0.015°C |
| Stability @ 650°C | ±0.025°C |
| Display Resolution | 0.01°C |
| Heating Time (30°C to 650°C) | 20 minutes |
| Cooling Time (650°C to 150°C) | 60 minutes |
| Calibration Volume | 35 mm diameter × 148 mm deep |
| Thermocouple Accuracy (E, J, K, N @ 660°C) | ±0.2°C |
| Thermocouple Accuracy (R @ 660°C) | ±0.6°C |
| Thermocouple Accuracy (S @ 660°C) | ±0.7°C |
| RTD Accuracy | ±0.05°C ±0.005% RDG |
| Blackbody Source Accuracy | ±0.3°C |
| Surface Sensor Accuracy | ±0.5°C |
| Power Supply | 115V or 230V AC, 50/60 Hz, 1000 Watts |
| Dimensions | 384 mm H × 212 mm W × 312 mm D |
| Weight | 8.5 kg |