BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Fluke Calibration 9144-E-P Dry-Well Field Calibrator

Fluke Calibration 9144-E-P Dry-Well Field Calibrator

Fluke Calibration · Model: 9144-E-P Made to order
Fluke Calibration 9144-E-P Dry-Well Field Calibrator
Request a quote

Fluke Calibration 9144-E-P is a portable dry-well field calibrator with 50°C to 660°C range, built-in two-channel readout, Insert E included, and ±0.01°C reference accuracy for transmitter loop cal...

Model 9144-E-P
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9144-E-P is a portable field metrology well equipped with process electronics for comprehensive temperature calibration. It combines the stability and accuracy of a precision dry-well with integrated measurement capabilities for RTD, thermocouple, and current loop signals. Supplied with Insert E for metric probe accommodation, it is designed for on-site transmitter loop calibration and sensor verification in industrial environments.

Key Features

  • Temperature range: 50°C to 660°C with rapid response (15 minutes to reach temperature)
  • Built-in two-channel readout for PRT, RTD, thermocouple, and 4-20 mA measurements with 24V loop supply
  • Insert E included: accommodates 4 mm, 6 mm, 8 mm, 10 mm, and 1/4 inch metric probe holes
  • High-accuracy reference thermometry with ±0.01°C uncertainty
  • Automated thermal switch testing capability
  • On-board data logging and documentation of up to 20 tests
  • Compatible with Fluke 754 Process Calibrator
  • Large LCD display and easy-to-navigate menu system
  • Lightweight and portable design for field deployment

Applications

  • Temperature transmitter loop calibration
  • RTD and PRT calibration and verification
  • Thermocouple calibration
  • Thermal switch testing
  • Industrial thermometer verification

Included Accessories

  • Insert E (metric misc: 4 mm, 6 mm, 8 mm, 10 mm, 1/4 in holes)
  • RS-232 interface and 9930 Interface-it control software
  • Test leads and user manual
  • Technical manual on CD
Temperature Range 50°C to 660°C
Display Accuracy at 50°C ±0.35°C
Display Accuracy at 420°C ±0.35°C
Display Accuracy at 660°C ±0.5°C
Reference Accuracy ±0.01°C
Stability at 50°C ±0.03°C
Stability at 420°C ±0.04°C
Stability at 660°C ±0.05°C
Immersion Depth 150 mm
Measurement Inputs PRT, RTD, Thermocouple, 4-20 mA