BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Fluke Calibration 9144-D-P Dry-Well Field Calibrator

Fluke Calibration 9144-D-P Dry-Well Field Calibrator

Fluke Calibration · Model: 9144-D-P Made to order
Fluke Calibration 9144-D-P Dry-Well Field Calibrator
Request a quote

Fluke Calibration 9144-D-P is a portable dry-block temperature calibrator with -25°C to 660°C range, ±0.01°C reference accuracy, and built-in two-channel readout.

Model 9144-D-P
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9144-D-P is a portable dry-block field calibrator designed for temperature measurement and sensor calibration in industrial environments. It extends high-performance metrology to the field by combining portability and speed without compromising accuracy. The instrument rapidly reaches temperature setpoints and maintains excellent stability and uniformity across its broad operating range.

The 9144-D-P is ideal for loop calibration of temperature transmitters, thermocouple verification, RTD or PRT calibration, thermostatic switch testing, and general industrial thermometer verification.

Key Features

  • Temperature range from -25°C to 660°C (122°F to 1220°F)
  • Reference accuracy of ±0.01°C for traceable measurements
  • Built-in two-channel readout for PRT, RTD, thermocouple, and 4-20 mA measurements
  • Rapid temperature stability: reaches setpoint in approximately 15 minutes
  • Large LCD display visible in low-light environments
  • Visual and audible stability indicator
  • On-board automation and documentation of up to 20 tests
  • Metrology performance meets EA standards for accuracy, stability, uniformity, and loading

Applications

  • Temperature transmitter loop calibration
  • Thermocouple calibration and verification
  • RTD and PRT calibration
  • Thermostatic switch testing
  • Industrial thermometer verification
Temperature Range -25°C to 660°C (-13°F to 1220°F)
Display Accuracy ±0.35°C at 50°C, ±0.35°C at 420°C, ±0.5°C at 660°C
Reference Accuracy ±0.01°C
Stability ±0.03°C at 50°C, ±0.04°C at 420°C, ±0.05°C at 660°C
Radial Uniformity ±0.02°C at 50°C, ±0.05°C at 420°C, ±0.14°C at 660°C
Axial Uniformity (at 40 mm) ±0.05°C at 50°C, ±0.2°C at 420°C, ±0.3°C at 660°C
Immersion Depth 150 mm (5.9 in)
Cool-down Time 15 minutes (to -25°C)
Heat-up Time 15 minutes (to 660°C)
Measurement Channels Two-channel readout for PRT, RTD, thermocouple, 4-20 mA
Test Documentation On-board memory for up to 20 tests
Fluke Calibration 9144-D-P Dry-Well Field Calibrator

Request a quote

Fluke Calibration 9144-D-P Dry-Well Field Calibrator

Response within 24 hours
No obligation
Direct communication

By submitting this form, you agree to the processing of your personal data in accordance with our privacy policy.