Fluke Calibration 9144-A High Temperature Dry-Well Calibrator

Fluke Calibration · Model: 9144-A Made to order
Fluke Calibration 9144-A High Temperature Dry-Well Calibrator
Request a quote

Fluke Calibration 9144-A is an advanced high-temperature metrology well for field calibration from 50–660°C with built-in reference thermometry and two-channel measurement.

Model 9144-A
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9144-A is an advanced high-temperature field metrology well for comprehensive temperature sensor and transmitter calibration in industrial environments. Covering 50°C to 660°C, this metrology-grade dry-block calibrator includes a built-in two-channel thermometer readout for measuring PRTs, RTDs, thermocouples, and 4–20 mA transmitters with 24 V loop power. This single-instrument solution eliminates the need to carry multiple tools to the field.

Key Features

  • Temperature Range: 50°C to 660°C (122°F to 1220°F)
  • Display Accuracy: ±0.35°C at 50°C, ±0.35°C at 420°C, ±0.5°C at 660°C
  • Stability: ±0.03°C at 50°C, ±0.05°C at 420°C, ±0.05°C at 660°C
  • Radial Uniformity: ±0.02°C at 50°C, ±0.05°C at 420°C, ±0.10°C at 660°C
  • Axial Uniformity (40 mm): ±0.05°C
  • Two-channel readout with true reference thermometry to ±0.01°C
  • 24 V loop power for transmitter testing
  • On-board non-volatile memory for up to 20 test records with alphanumeric IDs
  • Automated thermostatic switch testing — auto or manual setup modes
  • IEC-17025 NVLAP-accredited calibration certificate
  • Heating Time: 15 minutes from 50°C to 660°C

Applications

  • Transmitter loop calibration with both sensor and electronics testing
  • Thermocouple calibration and verification
  • RTD and PRT sensor calibration
  • 4–20 mA transmitter calibration
  • Thermostatic switch testing and verification
Temperature Range 50°C to 660°C (122°F to 1220°F)
Display Accuracy ±0.35°C at 50°C, ±0.35°C at 420°C, ±0.5°C at 660°C
Stability ±0.03°C at 50°C, ±0.05°C at 420°C, ±0.05°C at 660°C
Radial Uniformity ±0.02°C at 50°C, ±0.05°C at 420°C, ±0.10°C at 660°C
Axial Uniformity (40 mm) ±0.05°C
Loading Effect ±0.015°C at 50°C, ±0.025°C at 420°C, ±0.035°C at 660°C
Hysteresis 0.1°C
Immersion Depth 150 mm (5.9 in)
Insert OD 24.4 mm (0.96 in)
Heating Time 15 minutes (50°C to 660°C)
Cooling Time 35 minutes (660°C to 50°C), 25 minutes (660°C to 100°C)
Resolution 0.01°C
Display LCD, °C or °F user-selectable
Operating Temperature 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental Conditions 13°C to 33°C (for specifications)
Size 290 mm × 185 mm × 295 mm (11.4 × 7.3 × 11.6 in)
Weight 7.7 kg (17 lbs)