Fluke Calibration 9143-A-P is a field metrology well for temperature calibration from 33–350°C with ±0.2°C accuracy and integrated process electronics.

Model 9143-A-P
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9143-A-P is a portable field metrology well designed for temperature calibration in industrial environments. Operating from 33°C to 350°C, it offers metrology-grade accuracy and stability for thermocouple, RTD, and transmitter loop calibration. The unit features gradient-temperature compensation to maintain stable performance in unstable field environments, with a small footprint and lightweight design for easy portability.

Key Features

  • Temperature range: 33°C to 350°C (91°F to 662°F)
  • Display accuracy: ±0.2°C full range
  • Stability: ±0.02°C at 33°C, ±0.02°C at 200°C, ±0.03°C at 350°C
  • Axial uniformity: ±0.04°C at 33°C, ±0.1°C at 200°C, ±0.2°C at 350°C
  • Radial uniformity: ±0.01°C at 33°C, ±0.015°C at 200°C, ±0.02°C at 350°C
  • Rapid heating: 5 minutes from 33°C to 350°C
  • Insert A with 1/4", 1/8", 3/16", and 3/8" holes for various probe sizes
  • Built-in two-channel thermometer readout for PRTs, RTDs, thermocouples, and 4-20 mA transmitters
  • LCD display selectable for °C or °F
  • Process electronics with 24V loop supply for transmitter testing

Applications

  • Temperature transmitter loop calibration
  • Thermocouple calibration and verification
  • RTD and PRT calibration
  • Thermostatic switch testing
  • Industrial thermometer verification

Included Accessories

  • Insert A with multiple hole sizes
  • RS-232 serial cable
  • 9930 Interface-it control software
  • Test leads
Temperature Range 33 to 350°C (91 to 662°F)
Display Accuracy ±0.2°C full range
Stability at 33°C ±0.02°C
Stability at 200°C ±0.02°C
Stability at 350°C ±0.03°C
Axial Uniformity at 40 mm ±0.04°C at 33°C; ±0.1°C at 200°C; ±0.2°C at 350°C
Radial Uniformity ±0.01°C at 33°C; ±0.015°C at 200°C; ±0.02°C at 350°C
Loading Effect ±0.015°C full range
Hysteresis 0.03°C
Resolution 0.01°C
Heating Time 5 min from 33°C to 350°C
Cooling Time 32 min from 350°C to 33°C
Immersion Depth 150 mm (5.9 in)
Insert Outer Diameter 25.3 mm (1.00 in)
Operating Temperature 0 to 50°C
Humidity 0 to 90% RH (non-condensing)
Weight 7.3 kg (16 lb)
Dimensions 290 × 185 × 295 mm (11.4 × 7.3 × 11.6 in)