Fluke Calibration 9142-D-P Dry-Well Field Calibrator

Fluke Calibration · Model: 9142-D-P Made to order
Fluke Calibration 9142-D-P Dry-Well Field Calibrator
Request a quote

Fluke 9142-D-P is a portable dry-well calibrator with -25°C to 150°C range, ±0.01°C reference accuracy, and two-channel readout for RTDs, thermocouples, and 4-20 mA loops.

Model 9142-D-P
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9142-D-P is a lightweight, portable field metrology well calibrator designed for temperature measurement and sensor calibration. It combines speed and portability without compromising accuracy, stability, uniformity, and loading performance. The 9142-D-P includes metric comparison inserts (Insert D with 2×3mm, 2×4mm, 2×6mm holes) and built-in process electronics for comprehensive field calibration.

This model accepts various probe sizes and provides built-in two-channel readout for PRTs, RTDs, thermocouples, and 4-20 mA current loops. The process electronics option eliminates the need to carry additional tools into the field, featuring integrated readout for resistance, voltage, 4-20 mA current, and 24 V loop power.

Key Features

  • Temperature range from -25°C to 150°C (at 23°C ambient)
  • Reference accuracy of ±0.01°C with NIST-traceable calibration
  • Well stability of ±0.01°C and radial uniformity of ±0.01°C
  • Reaches -25°C in 15 minutes and 150°C in approximately 15 minutes
  • Large, easy-to-read LCD display with visual and audible stability indicators
  • Pre-programmed calibration routines in onboard non-volatile memory (up to 20 tests)
  • One-button temperature setpoint control
  • Smart connector for plug-and-play reference readout
  • Metric comparison inserts (Insert D: 2×3mm, 2×4mm, 2×6mm holes)
  • Includes 9930 Interface-it software for automation and documentation

Applications

  • Loop calibration of temperature transmitters
  • Thermocouple calibration and verification
  • RTD and PRT calibration
  • Testing of thermostatic switches
  • Verification of industrial thermometers

Included Accessories

  • Insert D (metric comparison: 2×3mm, 2×4mm, 2×6mm)
  • Test leads for process electronics
  • Spare probe connector
  • Power cord
  • 9930 Interface-it software
  • NVLAP NIST-traceable calibration certificate
  • User's manual
Temperature Range -25°C to 150°C (at 23°C ambient)
Reference Accuracy ±0.01°C
Well Accuracy ±0.2°C (full range)
Stability ±0.01°C (full range)
Radial Uniformity ±0.01°C (full range)
Axial Uniformity ±0.05°C at 40 mm immersion depth
Immersion Depth 150 mm (6 inches)
Cool Time Reaches -25°C in approximately 15 minutes
Heat Time Reaches 150°C in approximately 15 minutes
Display Large LCD with stability indicator
Channels Two-channel readout for PRT, RTD, thermocouple, 4-20 mA
Inserts Insert D (metric comparison: 2×3mm, 2×4mm, 2×6mm)
Calibration IEC-17025 NVLAP-accredited, NIST-traceable