BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Fluke Calibration 9142-A-P Dry-Well Calibrator

Fluke Calibration 9142-A-P Dry-Well Calibrator

Fluke Calibration · Model: 9142-A-P Made to order
Fluke Calibration 9142-A-P Dry-Well Calibrator
Request a quote

Fluke Calibration 9142-A-P dry well calibrator with built-in process electronics for temperature and transmitter measurements, -25°C to 150°C, ±0.2°C accuracy.

Model 9142-A-P
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9142-A-P is a portable field metrology well with integrated process electronics for temperature calibration and transmitter measurement. It operates from -25°C to 150°C and combines high-accuracy temperature control with a built-in two-channel thermometer that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters. This all-in-one solution eliminates the need to carry multiple instruments for complete transmitter loop calibration in the field.

Key Features

  • Temperature range: -25°C to 150°C (-13°F to 302°F)
  • Display accuracy: ±0.2°C over full range
  • Stability: ±0.01°C full range
  • Axial uniformity at 40 mm: ±0.05°C full range
  • Radial uniformity: ±0.01°C full range
  • Loading effect: ±0.006°C full range
  • Built-in two-channel thermometer readout for PRTs, RTDs, thermocouples, and 4-20 mA transmitters
  • 24 V loop power supply for transmitter testing
  • Non-volatile memory for documentation of up to 20 tests
  • Compact and portable design (8.16 kg)

Applications

  • Temperature transmitter loop calibration with simultaneous electronics and sensor measurement
  • RTD and PRT calibration and verification
  • Thermocouple sensor testing
  • 4-20 mA transmitter measurement and calibration
  • Thermostatic switch testing
  • Field calibration of complete temperature measurement systems

Included Accessories

  • User's manual
  • Technical manual on CD
  • Serial cable
  • Report of calibration
  • Insert removal tool
Temperature Range -25°C to 150°C (-13°F to 302°F)
Display Accuracy ±0.2°C full range
Stability ±0.01°C full range
Axial Uniformity (at 40 mm) ±0.05°C full range
Radial Uniformity ±0.01°C full range
Loading Effect ±0.006°C full range
Hysteresis 0.025°C
Operating Conditions 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental Conditions 13°C to 33°C
Well Depth 150 mm (5.9 in)
Insert OD 30 mm (1.18 in)
Heating Time 16 min (23°C to 140°C), 23 min (23°C to 150°C), 25 min (-25°C to 150°C)
Cooling Time 15 min (23°C to -25°C), 25 min (150°C to -23°C)
Resolution 0.01°C
Display LCD, °C or °F user-selectable
Dimensions (H × W × D) 290 × 185 × 295 mm (11.4 × 7.3 × 11.6 in)
Weight 8.16 kg (18 lb)
Process Electronics Two-channel readout for PRTs, RTDs, thermocouples, and 4-20 mA transmitters with 24V loop supply