BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Fluke Calibration 9142-A Dry Well Calibrator

Fluke Calibration 9142-A Dry Well Calibrator

Fluke Calibration · Model: 9142-A Made to order
Fluke Calibration 9142-A Dry Well Calibrator
Request a quote

Fluke Calibration 9142-A portable dry well for temperature calibration, -25°C to 150°C, ±0.2°C accuracy with optional transmitter measurement electronics.

Model 9142-A
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9142-A is a portable field metrology well designed for temperature calibration in industrial and laboratory environments. It provides high-accuracy temperature control from -25°C to 150°C with excellent stability and uniformity characteristics, making it ideal for calibrating temperature transmitters, thermocouples, RTDs, and PRTs in the field. The optional process version includes built-in two-channel thermometer electronics for direct measurement of transmitter signals.

Key Features

  • Temperature range: -25°C to 150°C (-13°F to 302°F)
  • Display accuracy: ±0.2°C over full range
  • Stability: ±0.01°C full range
  • Axial uniformity at 40 mm: ±0.05°C
  • Radial uniformity: ±0.01°C
  • Loading effect: ±0.006°C
  • Hysteresis: 0.025°C
  • Large LCD display with °C/°F selection
  • Compact and lightweight design (8.16 kg)
  • Optional process version with two-channel thermometer readout

Applications

  • Temperature transmitter loop calibration
  • Thermocouple sensor verification and calibration
  • RTD and PRT calibration
  • Thermostatic switch testing
  • Industrial thermometer verification
  • Comparison calibration of temperature sensors

Included Accessories

  • User's manual
  • Technical manual on CD
  • Serial cable
  • Report of calibration
  • Insert removal tool
Temperature Range -25°C to 150°C (-13°F to 302°F)
Display Accuracy ±0.2°C full range
Stability ±0.01°C full range
Axial Uniformity (at 40 mm) ±0.05°C full range
Radial Uniformity ±0.01°C full range
Loading Effect ±0.006°C full range
Hysteresis 0.025°C
Operating Conditions 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental Conditions 13°C to 33°C
Well Depth 150 mm (5.9 in)
Insert OD 30 mm (1.18 in)
Heating Time 16 min (23°C to 140°C), 23 min (23°C to 150°C), 25 min (-25°C to 150°C)
Cooling Time 15 min (23°C to -25°C), 25 min (150°C to -23°C)
Resolution 0.01°C
Display LCD, °C or °F user-selectable
Dimensions (H × W × D) 290 × 185 × 295 mm (11.4 × 7.3 × 11.6 in)
Weight 8.16 kg (18 lb)