Request a quote

Fluke Calibration 9101-156 is a zero-point dry-well using solid-state cooling technology, providing bath-quality stability at 0°C (32°F) with ±0.02°C accuracy for calibrating thermocouples and temp...

Model 9101-156
Manufacturer Fluke Calibration
Category Dry Block Calibrators
Availability Made to order

Overview

The Fluke Calibration 9101-156 is a zero-point dry-well designed to provide an accurate, traceable reference point at 0°C (32°F) for thermocouple calibration and temperature sensor verification. Using advanced solid-state cooling technology instead of sealed water cells, it eliminates the risk of freezing and bursting during transport while providing bath-quality stability in a portable, self-contained package.

Key Features

  • Temperature: 0°C (32°F) fixed point
  • Stability: ±0.005°C
  • Total instrument error: ±0.02°C typical; ±0.05°C maximum (18–25°C ambient)
  • Stabilization time: Approximately 30 minutes
  • Temperature coefficient: ±0.005°C/°C
  • Solid-state cooling technology for reliability and durability
  • Adjustable electronic controller for convenient lab recalibration
  • Ready light indicates stable control at 0°C
  • Three wells: two 0.25" diameter × 6" deep, one 0.28" diameter × 6" deep
  • Includes telescoping inserts for various small diameters
  • Power: 115 VAC (±10%), 1 A or 230 VAC (±10%), 0.5 A, 50/60 Hz, 125 W
  • NIST traceable calibration included

Applications

  • Thermocouple reference junction calibration
  • High-accuracy thermocouple measurements
  • Temperature sensor verification and calibration
  • Laboratory calibration reference standard

Included Accessories

  • Set of telescoping inserts for small diameters
Temperature 0°C (32°F) fixed point
Stability ±0.005°C
Total Instrument Error ±0.02°C typical; ±0.05°C maximum (18–25°C ambient)
Stabilization Time Approximately 30 minutes
Temperature Coefficient ±0.005°C/°C
Well Dimensions 2 wells 0.25" diameter × 6" deep; 1 well 0.28" diameter × 6" deep
Size 12.25" H × 8.5" W × 5.75" D (311 × 216 × 146 mm)
Weight 12 lb (5.4 kg)
Power 115 VAC (±10%), 1 A or 230 VAC (±10%), 0.5 A, 50/60 Hz, 125 W
Cooling Technology Solid-state cooling