Fluke 9173-DW-R-156 Metrology Well
Fluke 9173-DW-R-156 Metrology Well with built-in reference thermometer input for high-temperature calibration from 50°C to 700°C with ±0.25°C accuracy.
Product details
| Model | 9173-DW-R-156 |
| Manufacturer | Fluke |
| Category | Dry Block Calibrators |
| Availability | Made to order |
Description
Overview
The Fluke 9173-DW-R is a high-performance calibration tool designed for thermometers operating between 50°C and 700°C. This model features a built-in reference thermometer input, making it suitable for use as a reference standard in laboratory and field calibration applications. With an immersion depth of 203 mm (8 in), it is particularly suitable for calibrating thermometers at high temperatures. The display accuracy of ±0.25°C at 700°C, combined with excellent stability and uniformity performance, dramatically reduces uncertainty budgets for high-temperature calibrations.
The Model 9173-DW-R minimizes temperature gradients, loading effects, and hysteresis, making calibration measurements more meaningful. It uses traceable, accredited PRTs and Fluke's proprietary electronics for consistent, repeatable accuracy. The integrated Tweener measurement technology can accommodate 100, 25, and 10-ohm PRTs with accuracy from ±0.006°C at 0°C to ±0.027°C at 661°C. The unit is compatible with Fluke's Model 9938 MET/TEMP II software for fully automated calibrations.
Key Features
- Temperature range: 50°C to 700°C
- Display accuracy: ±0.2°C at 425°C; ±0.25°C at 660°C
- Stability: ±0.005°C to 100°C; ±0.01°C to 425°C; ±0.03°C to 700°C
- Axial uniformity (60 mm): ±0.1°C at 100°C; ±0.25°C at 425°C; ±0.4°C at 700°C
- Radial uniformity: ±0.01°C at 100°C; ±0.025°C at 425°C; ±0.04°C at 700°C
- Built-in reference thermometer input compatible with 100, 25, and 10-ohm PRTs
- Well depth: 203 mm (8 in)
- Resolution: 0.001°C
- LCD display selectable between °C and °F
- RS-232 serial interface
- 8 temperature set points with ramp and soak control
Applications
- Laboratory and field temperature calibration with reference thermometry
- Calibration of RTDs (Resistance Temperature Detectors)
- Calibration of thermocouples
- Use as a reference standard for high-temperature measurements
Included Accessories
- Power cord
- RS-232 cable
- 9930 Interface-it Software with user's guide
- Report of Calibration with calibration label
- Getting Started Guide and User's Guide
Specifications
| Series | 9170 Series |
Request a quote