Additel ADT878PC-700-NO-110V Reference Dry Well Calibrator
Request a quote
Additel ADT878PC-700-NO-110V is a reference-grade dry well calibrator reaching 700°C with dual-zone control, touchscreen display, and process calibrator options.
Product details
| Model | ADT878PC-700-NO-110V |
| Manufacturer | Additel |
| Category | Dry Block Calibrators |
| Availability | Made to order |
Description
Overview
The Additel ADT878 is a reference-grade dry well calibrator designed for temperature calibration applications. Available in a 700°C temperature range (-33 to 700°C), the unit offers dual-zone control, a large touchscreen display, and reference-level accuracy. The Process Calibrator (PC) option adds external reference input capabilities and two-channel device readouts for comprehensive temperature sensor measurement and thermocouple calibration.
Key Features
- Reference-grade accuracy: ±0.1°C to ±0.25°C depending on temperature range
- Temperature range: -33 to 700°C with quick-to-temperature performance
- Large color touchscreen display with dual-zone control
- Full HART communicator for configuring HART transmitters
- Wi-Fi and Bluetooth capability for wireless connectivity
- Self-calibration feature using external reference probes
- Process Calibrator option with two-channel RTD and thermocouple measurement
- Automatic annealing procedures for PRT treatment
- Optional triple point of water (TPW) kit for automatic cell realization
- Quick-Push connectors for easy probe connections
Applications
- Temperature sensor calibration and verification
- Thermocouple calibration and testing
- RTD (resistance temperature detector) measurement and calibration
- HART transmitter configuration and documentation
- Reference standard maintenance with self-calibration capability
- PRT (platinum resistance thermometer) annealing and drift checking
Included Accessories
- Reference Dry Well with selected insert
- Power cable
- USB Cable
- Insert removal tool
- Thermal Shield
- Test leads (Process Calibrator models)
- ISO 17025 Accredited calibration certificate
Specifications
| Temperature Range | -33 to 700°C |
| Accuracy | Reference-grade, ±0.1–0.25°C depending on temperature |
| Display | Large color touchscreen |
| Control | Dual-zone |
| HART Communicator | Full |
| Wireless | Wi-Fi and Bluetooth |
| Self-Calibration | Yes, with external reference |
| Optional Process Calibrator | 2-channel RTD/thermocouple measurement, HART configuration |