Additel ADT878PC-700-D-220V Reference Dry Well Calibrator
Additel ADT878PC-700 reference dry well calibrator reaches 700°C with ±0.2°C accuracy, dual-zone control, and HART communicator for precision calibration.
Product details
| Model | ADT878PC-700-D-220V |
| Manufacturer | Additel |
| Category | Dry Block Calibrators |
| Availability | Made to order |
Description
Overview
The Additel ADT878PC-700 is a reference-grade dry well calibrator designed for high-temperature precision calibration applications reaching 700°C. The unit features a large color touchscreen display, dual-zone temperature control, and reference-level performance standards for both laboratory and field use. The Process Calibrator version integrates external reference measurement, dual-channel device under test monitoring, and a full HART communicator for transmitter configuration and calibration.
The system includes self-calibration capability using external reference probes, automatic PRT annealing procedures, and comprehensive data logging with task documentation features. These capabilities make it suitable for RTD and thermocouple verification, HART transmitter testing, and temperature sensor maintenance programs.
Key Features
- Temperature range from 33°C to 700°C (91.4°F to 1292°F)
- Accuracy of ±0.2°C at 33°C and 425°C, ±0.25°C at 660°C
- Dual-zone temperature control for superior stability and uniformity
- Large color touchscreen display with intuitive user interface
- Integrated HART communicator for transmitter configuration, calibration, and communication
- External reference temperature input for reference-based control
- Dual-channel readout for simultaneous RTD and thermocouple measurement
- Measurement capabilities for RTD, thermocouple, mA, voltage, and switch signals
- Self-calibration using external reference PRT with automated procedures
- Automatic PRT annealing with preset temperature profiles
- Data logging and documentation with snapshot feature and task recording
- Wi-Fi and Bluetooth connectivity for remote access
- Quick-push connectors for rapid sensor connections
Applications
- Laboratory and field calibration of RTD sensors and thermocouples
- Verification and maintenance of temperature measurement instruments
- Configuration and calibration of HART-enabled temperature transmitters
- High-temperature process measurement and control validation
- PRT annealing and drift monitoring (with optional triple point water kit)
- Temperature sensor certification and quality assurance programs
Included Accessories
- Reference dry well with selected insert
- Power cable
- USB cable
- Insert removal tool
- Thermal shield
- Test lead sets
- ISO 17025 accredited calibration certificate
Specifications
| Input Voltage | 220V |
| Temperature Range | 33 to 700°C (91.4 to 1292°F) |
| Accuracy | ±0.2°C at 33°C and 425°C, ±0.25°C at 660°C |
| Temperature Control | Dual-zone |
| Display | Color touchscreen |
| Calibration Channels | External reference plus 2 DUT channels |
| Measurement Types | RTD, thermocouple, mA, voltage, switch, HART |
| HART Communicator | Integrated with read/configure/calibrate capabilities |
| Self-Calibration | Yes, using external reference probe |
| PRT Annealing | Automatic with preset temperature profiles |
| Data Logging | Yes, with auto-step function and snapshot feature |
| Wireless Connectivity | Wi-Fi and Bluetooth |
Request a quote