BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Additel ADT878PC-425 Reference Dry Well Calibrator

Additel ADT878PC-425 Reference Dry Well Calibrator

Additel · Model: ADT878PC-425-NO-220V Made to order
Request a quote

Additel ADT878PC-425 reference dry well calibrator with ±0.2°C accuracy, dual-zone control, HART communicator, and automated self-calibration.

Model ADT878PC-425-NO-220V
Manufacturer Additel
Category Dry Block Calibrators
Availability Made to order

Overview

The Additel ADT878PC-425 is a reference-grade dry block calibrator designed for precision temperature measurement and calibration applications. With ±0.2°C accuracy across its 33 to 425°C range, it combines laboratory-grade performance with practical field capabilities. The dual-zone control system ensures rapid temperature achievement and exceptional uniformity, making it ideal for calibrating thermocouples, RTDs, and other temperature sensors.

Key Features

  • Reference-grade accuracy of ±0.2°C across full range
  • Dual-zone control for optimal temperature uniformity
  • Full HART communicator for transmitter configuration and diagnostics
  • Large color touchscreen display for intuitive operation
  • Wi-Fi and Bluetooth connectivity for remote operation
  • Automated self-calibration using external reference probe
  • Two-channel readout for simultaneous RTD and thermocouple measurement
  • Set point control by external reference temperature
  • Quick-Push connectors for rapid sensor connections
  • Task documentation and data logging capabilities

Applications

  • Temperature sensor calibration and verification
  • Thermocouple and RTD calibration
  • HART transmitter configuration and testing
  • Industrial temperature measurement system validation
  • Calibration laboratory reference standard

Included Accessories

  • Reference Dry Well with selected insert
  • Power cable
  • USB Cable
  • Insert removal tool
  • Thermal Shield
  • Test leads (2 sets)
  • ISO 17025 Accredited calibration certificate
Temperature Range 33 to 425°C (91.4 to 797°F)
Accuracy ±0.2°C at full range
Control System Dual-zone
Display Color touchscreen
Connectivity Wi-Fi, Bluetooth
HART Communicator Yes
Measurement Channels Two (RTD/thermocouple)
Self-calibration Yes
Set Point Control By external reference