BSL Equipment
Home / Calibration Instruments / Temperature Calibrators / Dry Block Calibrators / Additel ADT878-160-H-220V Reference Dry Well Calibrator

Additel ADT878-160-H-220V Reference Dry Well Calibrator

Additel · Model: ADT878-160-H-220V Made to order
Request a quote

Additel ADT878-160 is a reference-grade dry well calibrator with ±0.1°C accuracy, dual-zone control, and optional HART communicator for temperature sensor calibration.

Model ADT878-160-H-220V
Manufacturer Additel
Category Dry Block Calibrators
Availability Made to order

Overview

The Additel ADT878-160 Reference Dry Well Calibrator is a reference-grade temperature calibration instrument designed for calibrating temperature sensors, RTDs, and thermocouples. It operates from -40°C to 160°C with ±0.1°C accuracy and features dual-zone temperature control for improved stability and uniformity. The unit includes a large color touchscreen display and can be configured with an optional Process Calibrator module for expanded measurement and documentation capabilities.

Key Features

  • Temperature range: -40°C to 160°C (-40°F to 320°F)
  • Accuracy: ±0.1°C at full range
  • Dual-zone temperature control for enhanced stability
  • Large color touchscreen display
  • Self-calibration using external reference probe
  • Wi-Fi and Bluetooth connectivity
  • Reference-level performance in accuracy, stability, and uniformity
  • Quick to temperature setpoint
  • ISO 17025 Accredited calibration standard
  • Optional Process Calibrator module with full HART communicator

Applications

  • Calibration of temperature sensors and resistance temperature detectors (RTDs)
  • Thermocouple validation and calibration
  • HART transmitter configuration and verification
  • Process control instrument verification
  • Temperature measurement reference standard

Included Accessories

  • Reference Dry Well with insert
  • Power cable
  • USB cable
  • Insert removal tool
  • Silica gel plugs
  • Insulation plug
  • ISO 17025 Accredited calibration certificate
Temperature Range -40 to 160°C (-40 to 320°F)
Accuracy ±0.1°C at full range
Temperature Control Dual-zone
Display Color touchscreen
Self-Calibration Yes, with external reference probe
Connectivity Wi-Fi and Bluetooth
HART Communicator Optional (Process Calibrator module)
Measurement Channels 2 channels RTD, thermocouple, mA, voltage, switch (with PC option)
Calibration Standard ISO 17025 Accredited
Power Supply 220V, 50/60 Hz

Request a quote

Additel ADT878-160-H-220V Reference Dry Well Calibrator

Response within 24 hours
No obligation
Direct communication

By submitting this form, you agree to the processing of your personal data in accordance with our privacy policy.