Fluke Calibration 1586A is a precision data acquisition mainframe measuring thermocouples, PRTs, and thermistors with ±0.005°C accuracy and 40 input channels.

Model 1586A
Manufacturer Fluke Calibration
Category Data Loggers
Availability Made to order

Overview

The Fluke Calibration 1586A Super-DAQ is a precision data acquisition mainframe used to measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance. It can function as a multi-channel data logger for factory environments or as a precision reference instrument for laboratory sensor calibration and benchtop measurements.

Key Features

  • Temperature measurement accuracy: PRTs ±0.005°C (with DAQ-STAQ Multiplexer), Thermocouples ±0.5°C (with High-Capacity Module), Thermistors ±0.002°C
  • Up to 40 isolated universal input channels
  • Flexible configuration with internal High-Capacity Module and/or external DAQ-STAQ Multiplexer
  • Selectable scan speed up to 10 channels per second
  • Four operating modes: Scan, Monitor, Measure, and Digital Multimeter (DMM)
  • Real-time color trending display for up to four channels simultaneously
  • 6.5-digit display resolution for DC voltage, DC current, and resistance measurements
  • Current reversal function minimizes thermoelectric effects in PRT and RTD measurements
  • Automated sensor calibration with control of Fluke Calibration temperature sources (dry-wells, micro-baths)
  • Data storage of up to 20 MB to internal non-volatile memory or external USB drive
  • Data transfer and analysis via USB or LAN connection to Microsoft Excel
  • Administrator and user profiles for data security and test traceability
  • Mx + B scaling and channel offset zero function
  • Two independent user-defined alarms per channel for range monitoring

Applications

  • Thermal mapping and temperature validation in manufacturing
  • Process sensor calibration
  • Multi-channel temperature data acquisition and logging
  • Laboratory benchtop reference measurements
  • Use in pharmaceutical, biotechnology, food processing, aerospace, and automotive industries
PRT Accuracy ±0.005°C (with DAQ-STAQ Multiplexer)
Thermocouple Accuracy ±0.5°C (with High-Capacity Module and internal CJC)
Thermistor Accuracy ±0.002°C
Input Channels Up to 40 isolated universal inputs
Scan Speed Up to 10 channels per second
Display Resolution 6.5 digits for DC voltage, DC current, and resistance
Data Storage Up to 20 MB internal non-volatile memory
Maximum Input Voltage 50 V
Offset Voltage < 2 µV
Operating Modes Scan, Monitor, Measure, Digital Multimeter (DMM)