Teledyne LeCroy T3HVD7000-100 High-Voltage Differential Probe
Request a quote
Teledyne LeCroy T3HVD7000-100 is a high-voltage differential probe with 100 MHz bandwidth, ±700V/±7000V range, 40 MΩ input impedance, and ±2% measurement accuracy.
Product details
| Model | T3HVD7000-100 |
| Manufacturer | Teledyne LeCroy |
| Category | Active & Differential Probes |
| Availability | Made to order |
Description
Overview
The Teledyne LeCroy T3HVD7000-100 is a high-voltage differential probe designed for accurate and easy voltage measurements in both single-ended and differential configurations. With a 100 MHz bandwidth and the ability to handle up to ±7000V common mode voltage, it is suitable for use with any oscilloscope equipped with a 1 MΩ BNC input.
Key Features
- Bandwidth: 100 MHz (-3 dB)
- Rise time: ≤3.5 ns
- Attenuation/Range selection: 100x / 1000x
- Max differential voltage: 100x ±700V / 1000x ±7000V
- Common mode voltage: ±7000V (DC + Peak AC)
- Input impedance: 20 MΩ (single-ended) / 40 MΩ (between inputs)
- Input capacitance: 5 pF (single-ended) / 2.5 pF (between inputs)
- Measurement accuracy: ±2%
- Over-voltage alarm with dual indicators
- Switchable bandwidth limit to reduce noise
- Compatible with any oscilloscope with 1 MΩ BNC input
Applications
- High-voltage circuit analysis
- Power electronics testing
- Differential signal measurement
- Field troubleshooting and validation
Included Accessories
- Alligator clips (T3HVD1500-70 and T3HVD1500-200 models)
- Alligator clips (T3HVD7000-100 model)
- Pincer clips
- Hook clips
- 1m T3HVD extender leads (x2)
- 1m T3HVD BNC-to-BNC cable
- 1.5m T3HVD USB A-to-B power cable
- USB power supply
Specifications
| Bandwidth | 100 MHz |
| Attenuation | 100X, 1000X |
| Input Capacitance | 2.5 pF |
| Maximum Input Voltage | 2300 V |
| Input Impedance | 40 MΩ |
| Interface | BNC |
| Cable Length | 1 m |
| Series | T3HVD Series |
| Operating Temperature Range | 0 to 50°C |
| Risetime | 3.5 ns |
| Safety Rating | CAT2 } CAT3 |
| Type | Differential Probe |
Request a quote
Teledyne LeCroy T3HVD7000-100 High-Voltage Differential Probe
Response within 24 hours
No obligation
Direct communication