Fluke Calibration 5618B-12-P Secondary PRT Probe
Fluke Calibration 5618B-12-P is a secondary-standard Platinum Resistance Thermometer probe with 12-inch immersion, 3.2mm sheath, ITS-90 calibration, and INFO-CON termination for 1523/1524 thermomet...
Product details
| Model | 5618B-12-P |
| Manufacturer | Fluke Calibration |
| Category | Temperature Probes & Sensors |
| Availability | Made to order |
Description
Overview
The Fluke Calibration 5618B-12-P is a secondary-standard Platinum Resistance Thermometer (PRT) probe designed for precision temperature measurement and calibration in critical applications. With a 3.2 mm diameter sheath and 12-inch immersion depth, it combines accurate measurements with reduced response time, making it ideal for applications where space is limited. Each probe includes NVLAP-accredited calibration with ITS-90 coefficients and is traceable to NIST standards.
The small diameter design minimizes heat conduction between the ambient environment and the sensor, reducing measurement errors in shallow immersion depth applications where larger probes would conduct excess heat.
Key Features
- Secondary-level performance with full ITS-90 calibration and NIST traceability
- Small diameter sheath (3.2 mm / 0.125 in) for reduced response time and minimal immersion errors
- INFO-CON termination for direct compatibility with Fluke Calibration 1523 and 1524 thermometers
- Excellent long-term stability and low drift rate
- NVLAP-accredited calibration with ITS-90 coefficients and R vs. T values
- 316 stainless steel sheath for durability and corrosion resistance
- Temperature range from -200°C to 500°C
Applications
- Temperature measurement and calibration in laboratory and industrial settings
- Calibration of infrared blackbody heat sources and IR calibrators
- Use with Fluke Calibration 1523, 1524, 1502A, 1529, or 1560 thermometer readouts
- Precision temperature monitoring where immersion depth is limited
- Industrial standard temperature measurements and traceability applications
Included Accessories
- NVLAP-accredited calibration report with ITS-90 calibration coefficients and R vs. T values
Specifications
| Sensor Type | Platinum Resistance Thermometer (PRT) |
| Resistance at 0°C | Nominal 100 Ω |
| Temperature Coefficient | 0.003923 Ω/Ω/°C |
| Temperature Range | -200°C to 500°C |
| Probe Length | 305 mm (12 in) |
| Sheath Diameter | 3.2 mm (0.125 in) |
| Sheath Material | 316 Stainless Steel |
| Lead Wire | 22 AWG Teflon-insulated, 6 ft |
| Stability/Drift Rate | ±0.1°C when used periodically to 500°C |
| Hysteresis | Less than 0.01°C |
| Time Constant | 9 seconds maximum (63.2%) |
| Thermal EMF | Less than 25 mV at 420°C |
| Calibration Standard | NVLAP-accredited, ITS-90, -200°C to 500°C |
| Termination Type | INFO-CON for 1523/1524 thermometers |