ITECH IT7915-350-90 Regenerative Grid Simulator
Request a quote
ITECH IT7915-350-90 15 kVA programmable four-quadrant regenerative grid simulator with 350V/90A output, 0.1% accuracy, supporting grid-tied and off-grid device testing.
Product details
| Model | IT7915-350-90 |
| Manufacturer | ITECH |
| Category | Power Supplies & Electronic Loads |
| Availability | Made to order |
Description
Overview
The ITECH IT7915-350-90 is a 15 kVA programmable four-quadrant regenerative grid simulator from the IT7900 series. It functions as both a grid simulator and power amplifier for testing grid-connected equipment, energy storage systems, microgrids, and power conversion systems. The unit features high power density at 15 kVA in 3U form factor and supports parallel connection for extended power ratings up to 960 kVA.
Key Features
- Four-quadrant regenerative operation with 100% current rating in source and sink modes
- 15 kVA power with 350 V / 90 A output, 0.01V/0.01A resolution
- Accuracy: 0.1% + 0.1% FS (voltage/current), 0.3% + 0.3% FS (power)
- High power density: 15 kVA in 3U rack space
- Programmable output impedance for real-world grid simulation
- Frequency range 16–150 Hz with selectable single-phase, three-phase, and reversed-phase modes
- Professional anti-islanding test mode with configurable RLC parameters
- Multiple compliance test modes: LVRT, phase jump, frequency variation, harmonic injection
- Supports IEC 61000-4-11/4-13/4-14/4-28 regulatory testing
- Master/slave parallel connection: up to 64 units for 960 kVA total power
- Waveform modes: sine, triangular, sawtooth, square, trapezoidal, clipped sine
- Data logging: up to 7 hours of continuous recording at 100 ms intervals
- Interfaces: USB, CAN, LAN with SCPI protocol; optional GPIB, analog, RS-232
Applications
- Grid-tied inverter and photovoltaic system testing
- Energy storage system (ESS) and battery converter testing
- Microgrids and distributed generation testing
- Power quality simulation and compliance testing
- Phase jump, frequency variation, and harmonic injection testing
- Anti-islanding protection verification
- Hardware-in-the-loop (HIL) and power hardware-in-the-loop (PHiL) applications
Specifications
| Regenerative 4-Quadrant AC Grid Simulator | The IT7900 series represent the newest generation of programmable, full four-quadrant grid simulators with full 100% of current rating in both source and sink mode, and provides energy recovery capability. The power generated by the DUT during the test can be easily fed back to the AC grid, rather than being dissipated as heat,which protects the environment and lowers the cost of operation. It can be applied to the applications in testing grid-tied products that inject energy into the grid, such as the frequency changes, voltage transients and DC injection of grid-tied/off-grid inverters testing. |
| Full 4-Quadrant Power Amplifier | The IT7900 series regenerative grid simulator can be used as a power amplifier to complete power hardware in the loop (PHIL) applications for microgrids, energy storage and new energy vehicles. The digital I/O or a standard suite of analog signal can be input via an external analog interface (optional) and then amplified without distortion to a real power waveshape with an external analog response time of less than 200us. |
| Anti-Islanding Test Mode | To meet the certification test of anti-islanding effect for grid-tied products, the IT7900 series provide a professional anit-islanding test mode. Users can adjust RLC parameters or configure the parameters of active power and reactive power to achieve the effect of simulating purely resistive or nonlinear grid loads, and further verify the anti-islanding protection response time of grid-tied DUTs under different equivalent impedances, three-phase load balancing and non-balancing conditions. The solution helps engineers to simplify the test circuit and cost savings of additional equipment such as oscilloscopes and power meters. |
| Master/Slave Parallel, Power up to 960kVA | IT7900 series can be master-slave paralleled to get higher current and power. Maximum 64 sets can be paralleled to reach 960kVA, the parallel is flexible and convenient. IT7900 comes with synchronous On/Off input and output signals, which ensure the synchronization of paralleling and ensures synchronous current sharing of multiple modules. After paralleling, all functions are retained and there’s no loss of accuracy, making the construction of the power system faster, more flexible, and more economical, either it is a stand-alone test or ATE system. |
| Trend Analysis | Thanks to the function of large data recording, IT7900 series is capable of recording up to 7 hours of continuous data at short intervals (fastest: 100ms). And it’s easy to view the complete curve generating from the start to the end of the test by the mode ‘trend’. There are six curves that can be displayed at the same time at most. In addition, you can slide the vernier calipers on the screen to check the exact data at a particular point in the current trend curves. It is useful for analyzing errors during test for a long time or inflection points during loading, etc. Besides, you can export the test data for further analysis by a USB. |
| Built-in Various Type of Distorted Waveforms | In addition to sine waveform, IT7900 series provides various standard AC waveforms, such as triangular wave, sawtooth wave, square wave, trapezoidal wave and clipped sine wave. These waves can be easily recall from the menu and displayed in the LCD touch screen. Moreover, in combination with sequence programming function, users can realize multiple waveform continuous output, to cope with complex power line disturbance test. |
| IT7915-350-90 | 350 V90 A15kVA0.01V/0.01A<0.1%+0.1%FS/<0.3%+0.3%FSUSB, CAN, LAN, digital I/O, optional GPIB / analog & RS232 3 u |