AstroNova UNIV-6 Universal Module
Request a quote
AstroNova UNIV-6 is a 6-channel universal input module for voltage and strain/bridge measurements with 800 kS/s sampling rate, 16-bit resolution, and Cat II isolation.
Product details
| Model | UNIV-6 |
| Manufacturer | AstroNova |
| Category | Multimeters & DMMs |
| Availability | Made to order |
Description
Overview
The AstroNova UNIV-6 is a 6-channel universal input module for the TMX data acquisition system. It accepts voltages up to 250 Vrms and supports full-bridge, half-bridge, and quarter-bridge sensors, providing maximum flexibility for acquiring different types of analog inputs with a single module.
Key Features
- 6 voltage or strain/bridge input channels
- Simultaneous sampling at up to 800 kS/s per channel
- 16-bit resolution
- 5 measurement ranges to maximize resolution
- Built-in counter and timer functions
- 250 VRMS or DC Cat II isolation
- 4-pole Bessel anti-aliasing filter
Applications
- Troubleshooting and diagnostics
- Product testing and validation
- Low channel count and mixed-signal applications
Specifications
| Compatibility | TMX TMX-18 TMX-R |
| Typical Applications | Troubleshooting Product testing Low channel count and mixed-signal applications |
| Feature | Parameter |
| Channels Per Module | 6 |
| Sample Rate | 800 kS/s/ch (400 KS/s/ch when using TMX-E or TMX-R) |
| Rated Isolation | 250 VRMS or DC, Cat II (iso-common to chassis and other iso-commons) |
| A/D | 16-bit SAR (one per channel) |
| Frequency Counter Capability | Yes, first channel. Software selectable. |
| Anti-Aliasing Filter | 4 pole Bessel |
| Counter Modes | Gated time frequency counter Cycle based frequency counter Pulse counter Pulse width detector Period width detector Duty cycle detector |
| Frequency ctr Range (menu) | Up to 120 kHz |
| Frequency ctr Range (spec’d) | 2 – 100 kHz (48 Hz – 100 kHz for cycle based frequency counter) |
| Frequency ctr Accuracy | +/- 0.07% of Measurement +.002 Hz |
| Min Counter Input Amplitude | 25% of span for freq and pulse counters 90% of span for all other modes |
| Pulse Counter Range | 64000000 maximum. (16 bit display resolution) |
| Pulse Width Accuracy | 0.7 μs +.00167% of span |
| Pulse Width Range | 10 μs – 40000 μs |
| Edge Separation Accuracy | .002% of measurement + .00167% of span + 0.7 μs |
| Edge Separation Range | 25 μs – 5000000 μs |
| Period Width Accuracy | .02% of measurement + .00167% of span + 1.0 μs |
| Period Width Range | 5 μs – 90000 μs (11 Hz – 200 kHz) |
| Duty Cycle Accuracy | .5% (Inputs in the 15 Hz – 10 kHz range with 20% – 80% duty cycles) |
| Counter Timebase | 50 MHz |
| Cold Start Drift | < 0.1% of attenuator (60 min.) |
| UNIV-6 | 6-Channel Universal Module Voltage and DC Bridge32850000 |
Request a quote
AstroNova UNIV-6 Universal Module
Response within 24 hours
No obligation
Direct communication