Fluke Calibration · Model: 5720A-03 Made to order
Fluke Calibration 5720A-03 Multifunction Calibrator
Request a quote

Fluke Calibration 5720A-03 is a five-function electrical calibrator with DC/AC voltage and current, and resistance, featuring wideband voltage option extending to 30 MHz for RF measurements.

Model 5720A-03
Manufacturer Fluke Calibration
Category Multifunction Calibrators
Availability Made to order

Overview

The Fluke Calibration 5720A-03 is a five-function electrical calibrator designed to address the full electrical calibration workload. It sources direct and alternating voltage and current, and resistance with specifications optimized for precision calibration of high-performance test equipment. The model 5720A-03 includes a wideband voltage option (03) that extends overall AC bandwidth to 10 Hz to 30 MHz, enabling calibration of RF voltmeters and high-frequency measurement equipment.

Key Features

  • DC voltage to 1100 V
  • AC voltage to 1100 V, output available from 10 Hz to 1.2 MHz (extended to 30 MHz with option 03)
  • AC and DC current to 2.2 A, output available from 10 Hz to 10 kHz
  • Resistance measurement and sourcing capabilities
  • Internal environmentally-controlled references for stable performance over wide ambient temperature range
  • Automatic meter error calculation with display of linearity, offset, and scale errors
  • Programmable entry limits to restrict accessible output levels and prevent equipment damage
  • Offset and scaling modes for simplified linearity testing of multimeters
  • Variable phase reference signal output and phase-lock input
  • Keys for multiplying and dividing output value by 10

Applications

  • Calibration of RF voltmeters and high-frequency measurement equipment
  • Precision calibration of digital multimeters and electrical test instruments
  • Production and service calibration environments
DC Voltage 0 to 1100 V
AC Voltage 0 to 1100 V, 10 Hz to 1.2 MHz (30 MHz with option 03)
DC Current 0 to 2.2 A
AC Current 1 to 2.2 A rms, 10 Hz to 10 kHz
Resistance Available
AC Bandwidth (Standard) 10 Hz to 1.2 MHz
AC Bandwidth (Option 03) 10 Hz to 30 MHz