Fluke 5500A/COIL 50-Turn Current Coil
Request a quote
Fluke 5500A/COIL 50-Turn Current Coil extends the current capabilities of the Fluke 5500A calibrator for high-current measurement and testing applications.
Product details
| Model | 5500A/COIL |
| Manufacturer | Fluke |
| Category | Multifunction Calibrators |
| Availability | Made to order |
Description
Overview
The Fluke 5500A/COIL 50-Turn Current Coil is an accessory designed to extend the current sourcing capabilities of the Fluke 5500A Multifunction Calibrator. This 50-turn transformer allows measurement and simulation of higher current values in applications requiring extended current ranges.
Key Features
- 50-turn transformer design for current multiplication
- Compatible with Fluke 5500A Multifunction Calibrator
- Enables measurement of higher current values
Applications
- Extending current sourcing capabilities for electrical calibration
- Current transformer testing and measurement
- High-current circuit testing and validation
Specifications
| Features | Parameters |
| Voltage DC | Range: 0 to ±1020V Best 1 Year Specification: ±50 ppm of setting |
| Current DC | Range: 0 to ±11A Best 1 Year Specification: ±0.01% of setting |
| Resistance | Range: 0 to 3.29.999 MΩ Best 1 Year Specification: ±0.009% of setting |
| Voltage AC | Range: 1 mV to 1020V 10 Hz to 500 kHz, Sine Best 1 Year Specification: ±0.03% of setting |
| Current AC | Range: 29 m A to 11A 10 Hz to 10 kHz, Sine Best 1 Year Specification: ±0.06% of setting |
| Capacitance | Range: 0.33 nF to 1.1 mF Best 1 Year Specification: ±0.25% of setting |
| RTD Source | Range: -200°C to +630°C (8 types) Best 1 Year Specification: ±0.03°C of setting |
| DC Power | Range: 109 mW to 11 kW Best 1 Year Specification: ± 0.08% of setting |
| AC Power | Range: 109 mW to 11 kW 45-65 Hz, PF=1 Best 1 Year Specification: ± 0.15% of setting |
| Phase | Range: 0 to ± 179.99° Best 1 Year Specification: ±0.15° |
| Frequency | Range: 0.01 Hz to 2.0 MHz Best 1 Year Specification: ±25 ppm of setting |
| Warm up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
| Settling Time | Less than 5 seconds for all functions and ranges except as noted |
| Standard Interfaces | IEEE-488 (GPIB), RS-232, 5725A (5500A only) |
| Temperature Performance | Operating: 0°C to 50°C Calibration: (tcal): 15°C to 35°C Storage: -20°C to 70°C |
| Temperature Coefficient | Temperature coefficient for temperatures outside tcal ± 5°C is 10% of the 90-day specification (or 1-year, as applicable) per °C |
| Relative Humidity | Operating: < 80% to 30°C, < 70% to 40°C, < 40% to 50°C Storage: < 95%, non-condensing |
| Altitude | Operating: 3,050m (10,000 ft) maximum Non-operating: 12,200m (40,000 ft) maximum |
| Safety | Designed to comply with: IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010.1-92 |
| Analog Low Isolation | 20V |
| EMC | Designed to comply with FCC Rules Part 15 |
| Line Power | Line Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: ± 10% about line voltage setting |
| Power Consumption | 300 VA |
| Calibration Documentation | 17025 accredited report of calibration included |
| Dimensions | Height: 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit Width: 43.2 cm (17 in), standard rack width Depth: 47.3 cm (18.6 in) overall |
| Weight (without options) | 20 kg (44 lbs.) |
| Absolute Uncertainty Definition | 5500A and 5520A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated. |
| Specification Confidence Interval | > 99% |
| 5500A | Multi-Product Calibrator |
| 5500A/COIL | 50-Turn Current Coil |