BSL Equipment
Home / Calibration Instruments / Loop Calibrators / Fluke 709H Precision Current Loop Calibrator

Fluke 709H Precision Current Loop Calibrator

Fluke · Model: 709H Made to order
Fluke 709H Precision Current Loop Calibrator
Request a quote

Fluke 709H is a precision current loop calibrator with 0.01% reading accuracy, battery-powered operation, built-in HART communication support, and valve simulation capability.

Model 709H
Manufacturer Fluke
Category Loop Calibrators
Availability Made to order

Overview

The Fluke 709H is a precision current loop calibrator designed for field technicians and service professionals. It combines industry-leading 0.01% reading accuracy with a compact, rugged design powered by standard AAA batteries. The instrument features intuitive operation with a Quick-Set knob for rapid setup and includes built-in HART communication via a selectable 250Ω resistor. The 24 V DC loop power with mA Measure Mode enables comprehensive loop testing from -25% to 125%, while the Valve Test feature allows simulation of defined mA values for system diagnostics.

Key Features

  • Best-in-class 0.01% reading accuracy
  • 24 V DC loop power with mA Measure Mode (-25% to 125%)
  • Built-in selectable 250Ω resistor for HART communication
  • Resolution: 1 µA on mA ranges, 1 mV on voltage ranges
  • Adjustable span selection (0 to 20 mA or 4 to 20 mA)
  • Variable step and ramp time in seconds
  • Valve Test feature for mA value simulation
  • Auto Shutdown (adjustable up to 30 minutes) to conserve battery life
  • Simple two-wire connection for all measurements
  • Intuitive Quick-Set knob interface

Applications

  • Field calibration of transmitters and sensors
  • Loop testing and diagnostics
  • HART communication verification
  • Valve control simulation and testing

Included Accessories

  • Extended tooth alligator clip set
  • 75X-8014 stackable lead set
  • TP220 test probes
  • AC280 SureGrip hook clips
  • HART cable
  • Soft Case
  • Six AAA batteries (installed)
  • Product Manual CD-ROM
  • Quick Reference Guide
  • Safety Information
Accuracy 0.01% of reading
Loop Power 24 V DC
mA Measure Mode Range -25% to 125%
Resolution (mA ranges) 1 µA
Resolution (voltage ranges) 1 mV
Span Options 0 to 20 mA or 4 to 20 mA
HART Communication Built-in with 250Ω resistor
Power Source 6 AAA batteries
Auto Shutdown Adjustable up to 30 minutes
Connection Type Two-wire
Fluke 709H Precision Current Loop Calibrator

Request a quote

Fluke 709H Precision Current Loop Calibrator

Response within 24 hours
No obligation
Direct communication

By submitting this form, you agree to the processing of your personal data in accordance with our privacy policy.