Megger S1-568 provides 5kV insulation resistance testing with rapid battery charging, 8mA noise rejection, and multiple diagnostic modes for power utilities.

Model 1003-019
Manufacturer Megger
Category Insulation Resistance & Megohmmeters
Availability Made to order

Overview

The Megger S1-568 is a 5kV diagnostic insulation resistance tester designed for power utilities, service companies, and equipment manufacturers working in power generation, transmission, and distribution. It delivers class-leading performance with a 6mA charge current for rapid testing of capacitive loads and advanced noise rejection capabilities, making it one of Megger's most sophisticated DC insulation resistance testers.

Key Features

  • Selectable test voltages: 250V, 500V, 1kV, 2.5kV, 5kV with user-settable ranges
  • Resistance range: 10kΩ to 15TΩ @ 5kV for comprehensive measurement capability
  • 6mA output current for fast charging of capacitive loads
  • 8mA noise rejection plus four software filter options for accurate measurements
  • Multiple diagnostic test modes: Polarization Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Stepped Voltage (SV), and Ramp testing
  • Rapid-charge Li-ion battery (EC62133 standard) with operation from AC source when flat
  • Remote control via USB with Bluetooth compatibility for CertSuite Asset software
  • CAT IV 600V safety rating at altitudes up to 3000m
  • Intuitive interface with two rotary switches and large backlit display for easy operation
  • Rugged dual-case design with fire-retardant inner case and IP-rated protection
  • Advanced data storage with time/date stamping and results recall
  • Double-insulated test leads with 3kV equivalent rating (6kV single insulation)

Applications

  • Power generation, transmission, and distribution system testing
  • Factory floor automation for high-volume resistance testing
  • Substation maintenance and equipment diagnostics
  • Equipment manufacturer testing and repair validation
  • Utility maintenance and condition monitoring
Test Voltage Ranges 250V, 500V, 1kV, 2.5kV, 5kV
Resistance Range @ 5kV 10kΩ to 15TΩ
Output Current (Charge) 6mA
Noise Rejection 8mA from 1200V to 2500V
Test Voltage Accuracy ±4%, -0%, ±10V
Battery 11.1V, 5.2Ah Li-ion, EC62133 standard
Battery Life @ 5kV 6 hours typical with 100MΩ load
Operating from AC 90-264V rms, 50/60Hz, 100A
Safety Rating CAT IV 600V @ up to 3000m altitude
Diagnostic Tests IR, Timed IR, DAR, PI, DD, SV, Ramp
Remote Control USB and Bluetooth with CertSuite Asset software
Capacitance Range 10nF to 25µF
Current Range 0.01nA to 6mA
Display Range 10kΩ to 35TΩ digital; 100kΩ to 10TΩ analog