Model FMA-A2309
Manufacturer Newport Electronics
Category Flowmeters
Availability Made to order

Overview

The Newport Electronics FMA-A2309 is a thermal mass flow controller designed for precise gas flow regulation up to 10 SLM (standard liters per minute). This low-cost solution utilizes thermal technology to provide stable, accurate flow control with excellent repeatability. The controller comes standard with a 5-point NIST calibration certificate.

Key Features

  • Thermal technology mass flow control with 100:1 turndown ratio
  • Flow range: 0-10 SLM with ±1% accuracy (full scale including linearity)
  • Repeatability: ±0.15% full scale or better
  • Response time: 5 seconds with temperature coefficient ≤0.05% per 1°C
  • Linear 0-5 Vdc output (optional 4-20 mA); 1000 Ω min load
  • Electromagnetic normally-closed control valve with 0-5 Vdc input
  • Power supply: 24 Vdc @ 300 mA or 115/220 Vac with AC adaptor included
  • Minimum inlet pressure: 1 psi for ≤1 SLM controllers
  • Maximum gas pressure: 250 psig (Polyacetal) or 500 psig (316 SS)
  • Leak integrity: 1×10⁻⁶ cc/min of He or better
  • Wetted materials: Polyacetal or optional 316 stainless steel with FKM O-rings
  • Operating temperature: 0 to 50°C (32 to 122°F)
  • Connections: 1/4 FNPT or 1/4" compression fitting (SS models)
  • 5-point NIST calibration certificate included

Applications

  • Laboratory gas flow regulation and measurement
  • Industrial process control
  • Research and analytical applications
  • Precision gas metering systems
Flow Range 0 to 10 SLM
Accuracy ±1% of full scale including linearity
Repeatability ±0.15% full scale or better
Turndown Ratio 100:1
Response Time 5 seconds
Temperature Coefficient 0.05% full scale per 1°C or better
Pressure Coefficient 0.01% full scale per psi or better
Output Signal Linear 0 to 5 Vdc or 4 to 20 mA
Control Signal 0 to 5 Vdc
Operating Temperature 0 to 50°C (32 to 122°F)
Power Supply 24 Vdc @ 300 mA or 115/220 Vac with AC adaptor
Maximum Gas Pressure 250 psig (Polyacetal) or 500 psig (316 SS)
Minimum Inlet Pressure 1 psi for ≤1 SLM; 20 psi for >20 SLM
Leak Integrity 1 x 10⁻⁶ cc/min of He or better
Wetted Materials Polyacetal or 316 Stainless Steel with FKM O-rings
Connections 1/4 FNPT or 1/4" compression fitting
Weight 1.25 kg (2.75 lb) with power supply
Newport Electronics FMA-A2309 Mass Flow Controller 0-10 SLM