Fluke 5200A — precision AC voltage calibrator with 100 µV to 120 V RMS output, 100 Hz to 1 MHz frequency range, and up to 0.3% measurement accuracy.

Model 5200A
Manufacturer Fluke
Category Calibration Instruments
Availability Made to order

Overview

The Fluke 5200A is a precision alternating voltage source designed for high-performance AC calibration in laboratory and manufacturing environments. It delivers exceptional stability and accuracy over a broad frequency range from 100 Hz to 1 MHz, with operating specifications over 0°C to 50°C. The instrument provides precision amplitude control across six ranges from 1 mV to 100 V, with outputs from 100 µV RMS to 120 V RMS and up to 50 mA load current capability.

Key Features

  • Amplitude control across six ranges: 1 mV to 100 V with 1 nanovolt resolution on 1 mV range
  • Output capability: 100 µV RMS to 120 V RMS with 50 mA load current
  • Additional 1000 V range for control of external 5205A or 5215A Power Amplifiers
  • Frequency coverage: 100 Hz to 1 MHz with 0.01 Hz resolution on 100 Hz range
  • 20% overrange capability on amplitude and frequency ranges
  • Amplitude error measurement in two ranges: ±3% and ±0.3% with 10 ppm resolution
  • Phase-locked oscillator synchronizable to external source within ±1° phase angle
  • Quadrature output signal (1 V to 10 V RMS) for wattmeter calibration
  • 3 V pulse signal for frequency monitoring with external counter

Applications

  • Precision voltmeter and voltage source calibration
  • Wattmeter calibration using quadrature output
  • AC instrument verification in laboratory environments
  • Manufacturing and calibration laboratory use
Amplitude Ranges Six ranges: 1 mV to 100 V
Amplitude Resolution 1 nanovolt on 1 mV range; up to 0.1 mV on 100 V range
Output Voltage 100 µV RMS to 120 V RMS
Load Current Up to 50 mA
External Amplifier Control 1000 V range (5205A or 5215A)
Frequency Range 100 Hz to 1 MHz
Frequency Resolution 0.01 Hz on 100 Hz range; up to 100 Hz on 1 MHz range
Amplitude Error Measurement ±3% and ±0.3% ranges; 10 ppm resolution
Phase Stability ±1° phase angle; ±0.05°/kHz over ±2% band
Quadrature Output 1 V to 10 V RMS, 90° phase lead
Operating Temperature Range 0°C to 50°C